- Code: 959.26
- Description: Service System Board
Incremental counter reset exceeds maximum value.
- Remedy: Replace the controller board.
- Code: 959.27
- Description: Service System Board
Increment count failed due to maximum value limit.
- Remedy: Replace the controller board.
- Code: 959.28
- Description: Service System Board
Invalid SP memory configuration.
- Remedy: Replace the controller board.
- Code: 960.xx
- Description: Service Memory Error
RAM memory error: RAM soldered on the board is bad.
- Remedy: Replace the controller board.
- Code: 961.xx
- Description: Service Memory Failure
RAM memory error: slot 1 RAM is bad.
- Remedy: Replace the controller board.
- Code: 962.xx
- Description: Service Memory Failure
RAM memory error: slot 2 RAM is bad.
- Remedy: Replace the controller board.