  • Code: SVC H1
  • Description: Fuser lamp error
  • Causes: Circuitry that controls the fuser temperature has failed.
  • Remedy: 1 Check for proper input line voltage. Is line voltage correct? Go to step 2. Provide proper line voltage.
    2 Remove and reinstall fuser assembly. See “Fuser assembly removal”. Does error clear? Problem solved. Go to step 3.
    3 Check fuser connector for damage. Replace if necessary. Does error clear? Problem solved. Go to step 4.
    Turn printer off and check cable that connects engine controller board connector FUCN to fuser for proper connection, continuity, and pin shorts. Is cable okay? Go to step 5. Properly connect cable or replace if damaged. If error clears, problem solved, otherwise go to step 5.
    5 Replace fuser assembly. See “Fuser assembly removal”. Does error clear? Note: Fuser is a customer ordered supply. Problem solved. Replace LVPS. See “Low voltage power supply (LVPS) with cage removal”. If error does not clear, replace engine controller board. See “Engine controller board removal”.
  • Code: SVC H2
  • Description: Fuser temperature error (warmingup)
  • Causes: Fusing temperature is not reached within the warming-up time period.
  • Remedy: 1 Check for proper input line voltage. Is line voltage correct? Go to step 2. Provide proper line voltage.
    2 Remove and reinstall fuser assembly. See “Fuser assembly removal”. Does error clear? Problem solved. Go to step 3.
    3 Check fuser connector for damage. Replace if necessary. Does error clear? Problem solved. Go to step 4.
    Turn printer off and check cable that connects engine controller board connector FUCN to fuser for proper connection, continuity, and pin shorts. Is cable okay? Go to step 5. Properly connect cable or replace if damaged. If error clears, problem solved, otherwise go to step 5.
    5 Replace fuser assembly. See “Fuser assembly removal”. Does error clear? Note: Fuser is a customer ordered supply. Problem solved. Replace LVPS. See “Low voltage power supply (LVPS) with cage removal”. If error does not clear, replace engine controller board. See “Engine controller board removal”.
  • Code: SVC H3
  • Description: Fuser temperature error (printing)
  • Causes: Fusing temperature drops below fusing threshold during the printing process and does not reach fusing temperature again within alloted time.
  • Remedy: 1 Check for proper input line voltage. Is line voltage correct? Go to step 2. Provide proper line voltage.
    2 Remove and reinstall fuser assembly. See “Fuser assembly removal”. Does error clear? Problem solved. Go to step 3.
    3 Check fuser connector for damage. Replace if necessary. Does error clear? Problem solved. Go to step 4.
    Turn printer off and check cable that connects engine controller board connector FUCN to fuser for proper connection, continuity, and pin shorts. Is cable okay? Go to step 5. Properly connect cable or replace if damaged. If error clears, problem solved, otherwise go to step 5.
    5 Replace fuser assembly. See “Fuser assembly removal”. Does error clear? Note: Fuser is a customer ordered supply. Problem solved. Replace LVPS. See “Low voltage power supply (LVPS) with cage removal”. If error does not clear, replace engine controller board. See “Engine controller board removal”.
  • Code: SVC H4
  • Description: Fuser temperature high error
  • Causes: Fusing temperature rises above limit during printing process and does not return within the alloted time period.
  • Remedy: 1 Check for proper input line voltage. Is line voltage correct? Go to step 2. Provide proper line voltage.
    2 Remove and reinstall fuser assembly. See “Fuser assembly removal”. Does error clear? Problem solved. Go to step 3.
    3 Check fuser connector for damage. Replace if necessary. Does error clear? Problem solved. Go to step 4.
    Turn printer off and check cable that connects engine controller board connector FUCN to fuser for proper connection, continuity, and pin shorts. Is cable okay? Go to step 5. Properly connect cable or replace if damaged. If error clears, problem solved, otherwise go to step 5.
    5 Replace fuser assembly. See “Fuser assembly removal”. Does error clear? Note: Fuser is a customer ordered supply. Problem solved. Replace LVPS. See “Low voltage power supply (LVPS) with cage removal”. If error does not clear, replace engine controller board. See “Engine controller board removal”.
  • Code: SVC HA
  • Description: Fuser AC OFF error (relay off)
  • Causes: AC relay turned off due to an abnormal temperature.
  • Remedy: 1 Check for proper input line voltage. Is line voltage correct? Go to step 2. Provide proper line voltage.
    2 Remove and reinstall fuser assembly. See “Fuser assembly removal”. Does error clear? Problem solved. Go to step 3.
    3 Check fuser connector for damage. Replace if necessary. Does error clear? Problem solved. Go to step 4.
    Turn printer off and check cable that connects engine controller board connector FUCN to fuser for proper connection, continuity, and pin shorts. Is cable okay? Go to step 5. Properly connect cable or replace if damaged. If error clears, problem solved, otherwise go to step 5.
    5 Replace fuser assembly. See “Fuser assembly removal”. Does error clear? Note: Fuser is a customer ordered supply. Problem solved. Replace LVPS. See “Low voltage power supply (LVPS) with cage removal”. If error does not clear, replace engine controller board. See “Engine controller board removal”.
  • Code: SVC L1
  • Description: Beam detector error (BDT error)
  • Causes: Laser scanning beam is not detected by beam sensor.
  • Remedy: 1 Check LCN connection on laser assembly LDU board. Is connector properly connected? Go to step 2. Properly connect LCN cable. If error clears, problem solved, otherwise go to step 2.
    2 Check LCN connection on engine controller board. Is cable properly connected? Go to step 3. Properly connect LCN cable. If error clears, problem solved, otherwise go to step 3.
    3 Check cable that connects engine controller board LCN and LDU LCN connectors for continuity and shorted pins. Is cable okay? Replace laser unit assembly. “Laser unit assembly (printhead) removal”. Go to step 4. Replace cable. Go to step 4.
    4 Does error clear? Problem solved. Replace engine controller board. See “Engine controller board removal”.
Error Code