PrintCopy.info service

Kyocera ECOSYS P3045dn

Error Codes List page 2

  • Code: 0170
  • Description: Billing counting error A checksum error is detected in the main and engine backup memories for the billing counters.
  • Remedy: Data damage of EEPROM. Contact the Service Administrative Division.
    Defective PWB. Replace the main PWB or the engine PWB and check for correct operation.
  • Code: 0190
  • Description: Backup memory device error (engine PWB)
  • Remedy: Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 0800
  • Description: Image processing error JAM010x is detected twice.
  • Remedy: Defective main PWB. Replace the main PWB and check for correct operations page 1-5-22).
  • Code: 0840
  • Description: Faults of RTC Unable to communicate with the RTC device normally. The RTC data is mismatched due to dead battery or shortcircuit with the metal part.
  • Remedy: Other RTC device failure due to dead battery or short-circuit with the metal part. Restart the main unit and set the correct time from the operation panel. Repair it if the battery comes off from the main PWB.
    Defective main PWB. Replace the main PWB and check for correct operation.
  • Code: 1010
  • Description: Lift motor error (60/55/50 ppm model only) After cassette 1 is inserted, lift sensor does not turn on within 10 s. This error is detected five times successively.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Lift motor and engine PWB (YC13)
    Defective drive transmission system of the lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective lift motor. Replace the lift motor.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 1020
  • Description: PF lift motor 1 error (paper feeder) After cassette 2 is inserted, PF lift sensor 1 does not turn on. This error is detected four times successively.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 1 and PF main PWB (YC7)
    Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF lift motor. Replace the PF lift motor 1.
    Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us