Description: FAX control PWB system error Processing with the fax software was disabled due to a software problem.
Causes: FAX control PWB.
Remedy: 1. Turn the main power swtch off and after 5 seconds, re-mount the FAX controller PWB, then turn power on. 2. Reinstall the fax software. 3. Replace the FAX control PWB.
Code: 0060
Description: Control PWB mismatch Unmatching engine and engine sub boards. Defective engine subboard
Causes: Control PWB
Remedy: 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Replace the control PWB and check for correct operation.
Code: 0070
Description: FAX control PWB incompatible detection error Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted.
Causes: FAX control PWB (The FAX PWB installed will not be the one designed for the machine.
Remedy: 1. Install the FAX system designed for the model. 2. Reinstall the fax software.
Code: 0100
Description: Backup memory device error
Causes: EEPROM (Control PWB)
Remedy: 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Check that the EEPROM on the main circuit PWB is peroperly installed on the main circuit PWB and, if not, re-install it. 3. Replace the control PWB and check for correct operation.
Code: 0110
Description: Backup memory data error
Causes: EEPROM (Control PWB)
Remedy: 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Check that the EEPROM on the main circuit PWB is peroperly installed on the main circuit PWB and, if not, re-install it. 3. Replace the control PWB and check for correct operation.
Code: 0120
Description: MAC address data error For data in which the MAC address is invalid.
Causes: EEPROM (Control PWB)
Remedy: 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Check the MAC address on the network status page. 3. If it is blank, obtain an EEPROM with its MAC address written from the service support and install. 4. Replace the control PWB and check for correct operation.