PrintCopy.info service

Konica-Minolta bizhub Pro 1200P

Error Codes List page 120

  • Code: C-E001
  • Description: Message queue error. The message queue is insufficient or destroyed.
  • Causes: Overall control board (OACB)
  • Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.
  • Code: C-E002
  • Description: Message parameter value error. The parameter value is in excess of the permissible limits.
  • Causes: Overall control board (OACB)
  • Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.
  • Code: C-E003
  • Description: Source task error. The ID of the task that sends the message queue is undefined.
  • Causes: Overall control board (OACB)
  • Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.
  • Code: C-E004
  • Description: Receiving event error. The receiving event of the message is undefined.
  • Causes: Overall control board (OACB)
  • Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.
  • Code: C-E005
  • Description: Memory access abnormality.
  • Causes: Overall control board (OACB)
  • Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.
  • Code: C-E006
  • Description: Header readout address abnormality.
  • Causes: Overall control board (OACB)
  • Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.