PrintCopy.info service

Konica-Minolta bizhub C554

Error Codes List page 3

  • Code: C0216
  • Description: LCT up/down abnormality
    The upper limit sensor (PS2) is not blocked even after the set period of time has elapsed after the paper lift-up operation began.
  • Remedy: When LU-204 is installed: 1 Check the connector between M1-LCDB CN3 for proper connection, and correct as necessary. 2 Check the connector of M1 for proper drive coupling and correct as necessary. 3 Check the connectors between PS2-relay CN406- LCDB CN5 for proper connection, and correct as necessary. 4 PS2 I/O check, sensor check LUDB CN5-3 (ON) LU-204 4-G. 5 M1 operation check LUDB CN3-4 (ON) LU-204 3-G. 6 Replace M1. 7 LUDB ICP2 conduction check. 8 Replace LUDB.
    When LU-301 is installed: 1 Check the connector between M1-LCDB CN3 for proper connection, and correct as necessary. 2 Check the connector of M1 for proper drive coupling and correct as necessary. 3 Check the connectors between PS2-relay CN3-LCDB CN5 for proper connection, and correct as necessary. 4 PS2 I/O check, sensor check LUDB CN5-3 (ON) LU-301 4-G. 5 M1 operation check LUDB CN3-4 (ON) LU-301 3-G. 6 Replace M1. 7 LUDB ICP2 conduction check. 8 Replace LUDB.
  • Code: C1003
  • Description: PK communication error
    <When FS-535+PK-521 is installed> When a communication error is detected between the FS control board (FSCB) and the punch control board (PKCB).
  • Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace PKCB. 4 Replace FSCB.
  • Code: C1004
  • Description: FNS communication error
    <When FS-533, FS-534 or FS-535 is installed> When the FS control board (FSCB) is receiving data, a communication error is detected.
    <When JS-506 is installed> When the JS control board (JSCB) is receiving data, a communication error is detected.d
  • Remedy: When FS-533, FS-534 or FS-535 is installed: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace FSCB (FS-533/FS-534/FS-535)
    When JS-506 is installed: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace JSCB.
  • Code: C1005
  • Description: ZU communication error
    When the ZU control board (ZUCB) is receiving data, a communication error is detected.
  • Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace ZUCB.
  • Code: C1080
  • Description: RU communication error
    When the RU control board (RUCB) is receiving data, a communication error is detected.
  • Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace RUCB.
  • Code: C1081
  • Description: SD communication error
    <When FS-534+SD-511 or FS-535+SD-512 is installed> When a communication error is detected between the FS control board (FSCB) and the SD control board (SDDB).
  • Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace SDDB (SD-511/SD-512). 4 Replace FSCB (FS-534/FS-535).