PrintCopy.info service

Konica-Minolta bizhub C450i

Error Codes List page 1

  • Code: C0002
  • Description: Paper feed communication error (When PC-116, PC-216, PC-416, or PC-417 is installed)
    When the base board (BASEB) is receiving data, a communication error is detected.
  • Causes: • CPU board (CPUB)
    • Base board (BASEB)
    • PC control board (PCCB)
  • Remedy: 1. Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power switch.
    2. Correct or replace the connector connection between the main body and the paper feed cabinet if faulty.
    3. Check CPUB for proper installation and correct as necessary.
    4. Rewrite the firmware.
    5. PCCB F11 conduction check (PC-417)
    6. Replace PCCB. (PC-116/PC-216 / PC-416 / PC-417)
    7. Replace CPUB.
    8. Replace BASEB.
  • Code: C0104, C0105
  • Description: • C0104: Tray 3/4 feeder transportation motor failure to turn (When PC-417 is installed)
    • C0105: Tray 3/4 feeder transportation motor turning at abnormal timing (When PC-417 is installed)
    • C0104: The control circuit detects motor failure to turn while the motor is turning.
    • C0105: The control circuit detects motor turning while the motor remains stationary.
  • Causes: • Transport motor (M152)
    • PC control board (PCCB)
  • Remedy: 1. Check the connector between M152-PCCB CN5 for proper connection and correct as necessary.
    2. Check the connector of M152 for proper drive coupling and correct as necessary.
    3. M152 load check • Check code: 28 • Multi code: 51, 52, 53, 54 (bizhub C650i), 51, 53, 54 (bizhub C550i), 51, 52, 54 (bizhub C450i) • Control signal: PCCB CN5-1 to 8 • Location of electrical component: 7-K
    4. Replace M152.
    5. PCCB F300 conduction check
    6. Replace PCCB.
  • Code: C0106
  • Description: Tray 3 paper feed motor turning at abnormal timing (When PC-116 or PC-216 is installed)
    • The control circuit detects motor failure to turn while the motor is turning.
    • The control circuit detects motor turning while the motor remains stationary.
  • Causes: • Tray 3 paper feed motor (M111)
    • PC control board (PCCB)
  • Remedy: 1. Check the connector between M111-PCCB CN5 for proper connection and correct as necessary.
    2. Check the connector of M111 for proper drive coupling and correct as necessary.
    3. M111 load check • Check code: 28 • Multi code: 11, 12, 13, 14 (bizhub C650i), 11, 13, 14 (bizhub C550i), 11, 12, 14 (bizhub C450i) • Control signal: PCCB CN5-5 (CW/CCW) • Location of electrical component: PC-116/PC-216 4-C
    4. Replace M111.
    5. Replace PCCB.
  • Code: C0106
  • Description: Transfer LCT paper feed motor turning at abnormal timing (When PC-416 is installed)
    • The control circuit detects motor failure to turn while the motor is turning.
    • The control circuit detects motor turning while the motor remains stationary.
  • Causes: • Paper feed motor (M131)
    • PC control board (PCCB)
  • Remedy: 1. Check the connector between M131-PCCB CN5 for proper connection and correct as necessary.
    2. Check the connector of M131 for proper drive coupling and correct as necessary.
    3. M131 load check • Check code: 28 • Multi code: 1, 2, 3, 4 (bizhub C650i), 1, 3, 4 (bizhub C550i), 1, 2, 4 (bizhub C450i) • Control signal: PCCB CN5-5 (CW/CCW) • Location of electrical component: PC-416 4-J
    4. Replace M131.
    5. Replace PCCB.
  • Code: C0107
  • Description: Tray 3 vertical transport motor turning at abnormal timing (When PC-116 or PC-216 is installed)
    • The control circuit detects motor failure to turn while the motor is turning.
    • The control circuit detects motor turning while the motor remains stationary.
  • Causes: • Tray 3 vertical transport motor (M112)
    • PC control board (PCCB)
  • Remedy: 1. Check the connector between M112-PCCB CN5 for proper connection and correct as necessary.
    2. Check the connector of M112 for proper drive coupling and correct as necessary.
    3. M112 load check • Check code: 28 • Multi code: 21, 22, 23, 24 (bizhub C650i), 21, 23, 24 (bizhub C550i), 21, 22, 24 (bizhub C450i) • Control signal: PCCB CN5-13 (CW/CCW) • Location of electrical component: PC-116/PC-216 3 to 4-C
    4. Replace M112.
    5. Replace PCCB.
  • Code: C0107
  • Description: Transfer LCT vertical transport motor turning at abnormal timing (When PC-416 is installed)
    • The control circuit detects motor failure to turn while the motor is turning.
    • The control circuit detects motor turning while the motor remains stationary.
  • Causes: • Vertical transport motor (M132)
    • PC control board (PCCB)
  • Remedy: 1. Check the connector between M132-PCCB CN5 for proper connection and correct as necessary.
    2. Check the connector of M132 for proper drive coupling and correct as necessary.
    3. M132 load check • Check code: 28 • Multi code: 46, 47, 48, 49 (bizhub C650i), 46, 48, 49 (bizhub C550i), 46, 47, 49 (bizhub C450i) • Control signal: PCCB CN5-13 (CW/CCW) • Location of electrical component: PC-416 4-J
    4. Replace M132.
    5. Replace PCCB.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us