  • Code: C1103
  • Description: CD alignment motor/Fr malfunction <bizhub C3851FS> • The CD alignment plate home sensor/Fr (FSPS2) is not turned OFF (unblocked) even after the lapse of a given period of time after the CD alignment motor/Fr (FSM2) is turned ON at start from the home position. • The CD alignment motor/Fr (FSM2) is not drive completion after the set period of time has elapsed even after the start of driving. • The CD alignment plate home sensor/Fr (FSPS2) is not turned ON (blocked) even after the lapse of a given period of time after the CD alignment motor/Fr (FSM2) is turned ON at the initial operation.
  • Causes: • CD alignment motor/Fr (FSM2) • CD alignment plate home sensor/Fr (FSPS2) • FS control board (FSCB)
  • Remedy: 1. Check the connector between FSM2-relay CN22-FSCB CN10 for proper connection and correct as necessary. 2. Check the connector of FSM2 for proper drive coupling, and correct as necessary. 3. Check the connector between FSPS2-FSCB CN10 for proper connection and correct as necessary. 4. FSPS2 I/O check, sensor check • Control signal: FSCB CN10-7 • Location of electrical component: 24-Q 5. FSM2 operation check • Control signal: FSCB CN10-1 to 4 • Location of electrical component: 24-Q 6. Replace FSM2. 7. Replace FSCB.
  • Code: C1108
  • Description: Stapler motor home position return malfunction <bizhub C3851FS> • When the stapler unit starts driving from the home position, the stapler home sensor is not turned ON (blocked) even after the lapse of a given period of time after the stapler motor turned ON, and the stapler home sensor is not turned ON (blocked) even after the lapse of a given period of time after the stapler motor drives to the reverse direction. • When the stapler unit is returned to the home position, the stapler home sensor is not turned ON (blocked) even after the lapse of a given period of time after the stapler motor turned ON, and the stapler home sensor is not turned ON (blocked) even after the lapse of a given period of time after the stapler motor drives to the reverse direction.
  • Causes: • Stapler unit • FS control board (FSCB)
  • Remedy: 1. Check the connector between the stapler unit-relay CN43-FSCB CN5 for proper connection and correct as necessary. 2. Check the connector of the stapler unit for proper drive coupling, and correct as necessary. 3. Stapler home sensor I/O check, sensor check • Control signal: FSCB CN5-5 • Location of electrical component: 21-W 4. Replace the stapler unit. 5. Replace FSCB.
  • Code: C1109
  • Description: Stapler unit malfunction <bizhub C3851FS> The stapler home sensor is not turned OFF (unblocked) even after the lapse of a given period of time after the stapler motor turned ON.
  • Causes: • Stapler unit • FS control board (FSCB)
  • Remedy: 1. Check the connector between the stapler unit-relay CN43-FSCB CN5 for proper connection and correct as necessary. 2. Check the connector of the stapler unit for proper drive coupling, and correct as necessary. 3. Stapler home sensor I/O check, sensor check • Control signal: FSCB CN5-5 • Location of electrical component: 21-W 4. Replace the stapler unit. 5. FSCB ICP3 conduction check 6. Replace FSCB.
  • Code: C1140
  • Description: CD alignment motor/Rr malfunction <bizhub C3851FS> • The CD alignment plate home sensor/Rr (FSPS3) is not turned OFF (unblocked) even after the lapse of a given period of time after the CD alignment motor/Rr (FSM3) is turned ON at start from the home position. • The CD alignment motor/Rr (FSM3) is not drive completion after the set period of time has elapsed even after the start of driving. • The CD alignment plate home sensor/Rr (FSPS3) is not turned ON (blocked) even after the lapse of a given period of time after the CD alignment motor/Rr (FSM3) is turned ON at the initial operation.
  • Causes: Finisher Relevant electrical parts • CD alignment motor/Rr (FSM3) • CD alignment plate home sensor/Rr (FSPS3) • FS control board (FSCB)
  • Remedy: 1. Check the connector between FSM3-relay CN12-relay CN13-FSCB CN8 for proper connection and correct as necessary. 2. Check the connector of FSM3 for proper drive coupling, and correct as necessary. 3. Check the connector between FSPS3-relay CN13-FSCB CN8 for proper connection and correct as necessary. 4. FSPS3 I/O check, sensor check • Control signal: FSCB CN8-10 • Location of electrical component: 22-Q 5. FSM3 operation check • Control signal: FSCB CN8-1 to 4 • Location of electrical component: 21-Q 6. Replace FSM3. 7. Replace FSCB.
  • Code: C1146
  • Description: FD leading edge alignment motor malfunction <bizhub C3851FS> • The FD leading edge home sensor (FSPS1) is not turned OFF (unblocked) even after the lapse of a given period of time after the FD leading edge alignment motor (FSM1) is turned ON at start from the home position. • The FD leading edge alignment motor (FSM1) is not drive completion after the set period of time has elapsed even after the start of driving. • The FD leading edge home sensor (FSPS1) is not turned ON (blocked) even after the lapse of a given period of time after the FD leading edge alignment motor (FSM1) is turned ON at the initial operation.
  • Causes: • FD leading edge alignment motor (FSM1) • FD leading edge home sensor (FSPS1) • FS control board (FSCB)
  • Remedy: 1. Check the connector between FSM1-relay CN18-FSCB CN3 for proper connection and correct as necessary. 2. Check the connector of FSM1 for proper drive coupling, and correct as necessary. 3. Check the connector between FSPS1-FSCB CN5 for proper connection and correct as necessary. 4. FSPS1 I/O check, sensor check • Control signal: FSCB CN5-3 • Location of electrical component: 20-W 5. FSM1 operation check • Control signal: FSCB CN3-5 to 8 • Location of electrical component: 23-Q 6. Replace FSM1. 7. Replace FSCB.
  • Code: C1147
  • Description: FD trailing edge pushing motor malfunction <bizhub C3851FS> • The FD trailing edge home sensor (FSPS4) is not turned OFF (unblocked) even after the lapse of a given period of time after the FD trailing edge pushing motor (FSM4) is turned ON at start from the home position. • The FD trailing edge pushing motor (FSM4) is not drive completion after the set period of time has elapsed even after the start of driving. • The FD trailing edge home sensor (FSPS4) is not turned ON (blocked) even after the lapse of a given period of time after the FD trailing edge pushing motor (FSM4) is turned ON at the initial operation.
  • Causes: • FD trailing edge pushing motor (FSM4) • FD trailing edge home sensor (FSPS4) • FS control board (FSCB)
  • Remedy: 1. Check the connector between FSM4-relay CN20-FSCB CN3 for proper connection and correct as necessary. 2. Check the connector of FSM4 for proper drive coupling, and correct as necessary. 3. Check the connector between FSPS4-FSCB CN10 for proper connection and correct as necessary. 4. FSPS4 I/O check, sensor check • Control signal: FSCB CN10-10 • Location of electrical component: 24 to 25-Q 5. FSM4 operation check • Control signal: FSCB CN3-9 to 12 • Location of electrical component: 23-Q 6. Replace FSM4. 7. Replace FSCB.