  • Code: C027
  • Display: CONTROLLER ROM
  • Description: Controller ROM error (Data error)
    • Final check sum error is detected during the printer starting.
  • Remedy: 1 Reboot the main body. 2 Check the PRCB connector for proper connection and correct as necessary. 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again. 4 Change PRCB.
  • Code: C050
  • Display: HDD ERROR
  • Description: HDD access error
    • When correct access to the hard disk kit is failed during access.
  • Remedy: 1 Reboot the main body. 2 Check the HDD connector for proper connection and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change HDD. 5 Change PRCB.
  • Code: C051
  • Display: HDD DISK FULL
  • Description: HDD full error
    • Range for user space is full during access to the hard disk kit.
  • Remedy: 1 Reboot the main body. 2 Delete the job hold in “PROOF/PRINT MENU” to increase the available range for user space. 3 Check the HDD connector for proper connection and correct as necessary. 4 Format HDD with “SYS DEFAULT MENU/ HDD FORMAT.” 5 Change HDD.
  • Code: C052
  • Display: CARD ERROR
  • Description: Compact flash access error
    • When correct access to the compact flash card is failed during access.
  • Remedy: 1 Reboot the main body. 2 Check the compact flash for proper connection and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change compact flash. 5 Change PRCB.
  • Code: C053
  • Display: CARD FULL
  • Description: Compact flash full error
    • Range for user space is full during access to the compact flash card.
  • Remedy: 1 Reboot the main body. 2 Check the compact flash for proper connection and correct as necessary. 3 Change compact flash.pr
  • Code: C060
  • Display: UPDATE ERROR
  • Description: Firmware update error
    • Firmware update fails to complete correctly during update.
  • Remedy: 1 Reboot the main body. 2 Check the cable that has been used for update of the firmware for proper connection and correct as necessary. 3 Check the firmware update file and if the file is not the correct one, update the firmware again. 4 Check the firmware update procedure and if the procedure is not correct, update the firmware again. 5 Update the firmware again. . . 6 Check the PRCB connector for proper connection and correct as necessary. 7 Change PRCB.