Description: Exposure Lamp turning ON at abnormal timing
• The average output value of the CCD Sensor with the Scanner at its standby position is a predetermined value or more at the end of a scan job.
Remedy: 1 Check the flat cable for proper connection and correct or change as necessary. 2 Change Scanner Assy. 3 Change PWB-C.
Code: CA051
Description: Standard controller configuration failure
• The controller of the MFP Control Board (PWBMFP) is faulty.
Remedy: 1 Check to see if the following setting has been correctly made: [Service Mode] - [System 2] - [Image Controller Setting]. If changing the setting, turn OFF the Main Power SW and turn it ON again after 10 seconds or more. 2 Check the connectors of the MFP Control Board (PWB-MFP) for proper connection and correct as necessary. 3 Change PWB-MFP
Code: CA052
Description: Controller hardware error
• A controller hardware error is detected in the network I/F.
Remedy: 1 Check to see if the following setting has been correctly made: [Service Mode] - [System 2] - [Image Controller Setting]. If changing the setting, turn OFF the Main Power SW and turn it ON again after 10 seconds or more. 2 Check the connectors of the MFP Control Board (PWB-MFP) for proper connection and correct as necessary. 3 Change PWB-MFP
Code: CA053
Description: Controller start failure
• A controller start failure is detected in the controller interface.
Remedy: 1 Check to see if the following setting has been correctly made: [Service Mode] - [System 2] - [Image Controller Setting]. If changing the setting, turn OFF the Main Power SW and turn it ON again after 10 seconds or more. 2 Check the connectors of the MFP Control Board (PWB-MFP) for proper connection and correct as necessary. 3 Change PWB-MFP