  • Code: C027
  • Description: Controller ROM error (Data error) • Final check sum error is detected during the printer starting.
  • Remedy: 1 Reboot the main body. 2 Check the MFPB/1 connector for proper connection and correct as necessary. 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again. 4 Change MFPB/2.
  • Code: C050
  • Description: HDD access error • When correct access to the hard disk kit is failed during access.
  • Remedy: 1 Reboot the main body. 2 Check the HDD connector for proper connection and correct as necessary. 3 Check the MFPB/1 connector for proper connection and correct as necessary. 4 Change HDD. 5 Change MFPB/2.
  • Code: C051
  • Description: HDD full error • Range for user space is full during access to the hard disk kit.
  • Remedy: 1 Reboot the main body. 2 Delete the job hold in [PS/PCL PRINT] - [PROOF/PRINT MENU] to increase the available range for user space. 3 Check the HDD connector for proper connection and correct as necessary. 4 Format HDD with [SYS DEFAULT MENU] - [HDD FORMAT]. 5 Change HDD. 6 Change MFPB/2.
  • Code: C052
  • Description: Compact flash access error • When correct access to the compact flash card is failed during access.
  • Remedy: 1 Reboot the main body. 2 Check the compact flash for proper connection and correct as necessary. 3 Check the MFPB/1 connector for proper connection and correct as necessary. 4 Change compact flash. 5 Change MFPB/2.
  • Code: C053
  • Description: Compact flash full error • Range for user space is full during access to the compact flash card.
  • Remedy: 1 Reboot the main body. 2 Delete the job hold in [PS/PCL PRINT] - [PROOF/PRINT MENU] to increase the available range for user space. 3 Check the compact flash for proper connection and correct as necessary. 4 Format HDD with [SYS DEFAULT MENU] - [CARD FORMAT]. 5 Change compact flash. 6 Change MFPB/2.
  • Code: C060
  • Description: Firmware update error • Firmware update fails to complete correctly during update.
  • Remedy: 1 Reboot the main body. 2 Check the cable that has been used for update of the firmware for proper connection and correct as necessary. 3 Check the firmware update file and if the file is not the correct one, update the firmware again. 4 Check the firmware update procedure and if the procedure is not correct, update the firmware again. 5 Update the firmware again. 6 Check the MFPB/1 connector for proper connection and correct as necessary. 7 Change MFPB/2.