PrintCopy.info service

Konica-Minolta bizhub 951 Pro

Error Codes List page 4

  • Code: C-0103
  • Description: 1st tandem PF-703/706 paper feed motor (M1) speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M1 was turned ON.
  • Causes: • Paper feed motor (M1: PF-703/706) • PF drive board (PFUDB: PF-703/706)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality (Wiring diagram: PF-703: 6-L, PF-706: 6-H) 3. Replace M1 4. Replace PFUDB
  • Code: C-0104
  • Description: Abnormality of the vertical conveyance motor (M8) power in the printer control board (PRCB). An error detection signal (blowout of ICP) of M8 is detected when M8 is turned ON.
  • Causes: • Vertical conveyance motor (M8) • Printer control board (PRCB)
  • Remedy: 1. Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, repair/replace it if any abnormality, and then replace the PRCB (Wiring diagram: Main body (3/4): 6-I). 3. Replace M8 and PRCB at a time.
  • Code: C-0105
  • Description: Abnormality of the PF exit conveyance motor (M2) power in the PF drive board (PFUDB) of the 1st tandem PF-706. An error detection signal (blowout of ICP) of M2 is detected when M2 is turned ON.
  • Causes: • PF exit conveyance motor (M2: PF-706) • PF drive board (PFUDB: PF-706)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality 2. Check the I/O drive of the motor and the coupling of the gear, repair/replace it if any abnormality, and then replace the PFUDB (Wiring diagram: PF-706: 7-H) 3. Replace M2 and PFUDB
  • Code: C-0106
  • Description: 2nd tandem PF-703/706 paper feed motor speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M1 was turned ON.
  • Causes: • Paper feed motor (M1: PF-703/706) • PF drive board (PFUDB: PF-703/706)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality (Wiring diagram: PF-703: 6-L, PF-706: 6-H) 3. Replace M1 4. Replace PFUDB
  • Code: C-0107
  • Description: Abnormality of the PF exit conveyance motor (M2) power in the PF drive board (PFUDB) of the 2nd tandem PF-706. An error detection signal (blowout of ICP) of M2 is detected when M2 is turned ON.
  • Causes: • PF exit conveyance motor (M2: PF-706) • PF drive board (PFUDB: PF-706)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality 2. Check the I/O drive of the motor and the coupling of the gear, repair/replace it if any abnormality, and then replace the PFUDB (Wiring diagram: PF-706: 7-H) 3. Replace M2 and PFUDB
  • Code: C-0108
  • Description: Abnormality of the PF conveyance motor (M3) power in the PF drive board (PFUDB) of the 1st tandem PF-703. An error detection signal (blowout of ICP) of M3 is detected when M3 is turned ON.
  • Causes: • PF exit conveyance motor (M3: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality 2. Check the I/O drive of the motor and the coupling of the gear, repair/replace it if any abnormality, and then replace the PFUDB (Wiring diagram: PF-703: 8-L) 3. Replace M3 and PFUDB at a time