PrintCopy.info service

Konica-Minolta bizhub 7616

Error Codes List page 4

  • Code: C1038
  • Description: Engine connection failure
    Master Board (PWB-A) to Control Board (PWB-C/C) connection failure
    - There is no acknowledge signal transmitted from the Master Board (PWB-A) to Control Board (PWB-C/C) for 1.5 sec. or more.
    - An error command signal is transmitted from the Control Board (PWB-C/C) to Master Board (PWB-A).
    - An error status signal is transmitted from the Master Board (PWB-A) to Control Board (PWB-C/C).
  • Remedy: 1 Turn OFF and ON the Power Switch. 2 Check the PWB-A connectors for proper connection and correct as necessary. 3 Check the PWB-C/C connectors for proper connection and correct as necessary. 4 Check for proper connection between PWB-A and PWB-C/C and correct as necessary. 5 Change PWB-A. 6 Change PWB-C/C.
  • Code: C1200
  • Description: Faulty ASIC/memory
    ASIC/memory (for image and control) fault
    A write or read error occurs with SRAM on the Control Board (PWB-C/C).
  • Remedy: 1 Turn OFF and ON the Power Switch. 2 Check memory on PWB-C/C for connection and correct as necessary. 3 Change PWB-C/C.
  • Code: C1300
  • Description: Polygon Motor malfunction
    -Startup failure
    - Lock signal fault: Unstable after the first Lock signal has been detected
    - Lock signal fault: Lock signal out-of-timing
  • Remedy: 1 Turn OFF and ON the Power Switch. 2 Check for proper connection between the PH Unit and Master Board and correct as necessary. 3 Change the PH Unit. 4 Change PWB-A.
  • Code: C133B
  • Description: Communication with option error
    - It is not possible to communicate with the Printer Board within a predetermined period of time during a print cycle.
  • Remedy:
  • Code: C133D
  • Description: ROM check error
    - An error is detected of the flash ROM chip on the Fax Board when the Power Switch is turned ON.
  • Remedy:
  • Code: C13F0
  • Description: Faulty HSYNC
    Laser scanning system malfunction
    - The SOS Sensor does not detect a rising edge of SOS within a given period of time after the Polygon Motor (M2) has started turning and a laser output has been started.
    - The SOS Sensor detects no rising edges of SOS while VIA (image area control) is ON.
  • Remedy: 1 Turn OFF and ON the Power Switch. 2 Check for proper connection between the PH Unit and Master Board and correct as necessary. 3 Change the PH Unit. 4 Change PWB-A.