PrintCopy.info service

Konica-Minolta bizhub 502

Error Codes List page 2

  • Code: C0216
  • Description: LCT up/down abnormality • The Upper limit sensor (PS2) is not blocked even after the set period of time has elapsed after the paper lift-up operation began.
  • Causes: Upper limit sensor (PS2) Lift-up motor (M1)
  • Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check the connector of M1 for proper drive coupling and correct as necessary. 3 PS2 I/O check, sensor check LUDB CN5-3 (ON) LU-204 G-4 4 M1 operation check LUDB CN3-4 (ON) LU-204 G-3 5 Change M1 6 LUDB ICP2 conduction check 7 Change LUDB
  • Code: C0301
  • Description: Suction fan motor’s failure to turn • The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
  • Causes: Suction fan motor (FM1) Paper feed/transport drive board (PFTDB)
  • Remedy: 1 Check the FM1 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM1 operation check PFTDB CN5-3 (REM) PFTDB CN5-5 (LOCK) Q-6 4 Change FM1 5 PFTDB ICP2 conduction check 6 Change PFTDB
  • Code: C0351
  • Description: Paper cooling fan trouble • The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
  • Causes: Paper cooling fan motor (FM13) Printer control board (PRCB)
  • Remedy: 1 Check the FM13 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM13 operation check PRCB CN15-7 (REM) PRCB CN15-9 (LOCK) K-9 4 Change FM13 5 PRCB ICP6 conduction check 6 Change PRCB
  • Code: C1003
  • Description: PK communication error <When FS-526+PK-516 is installed> • When a communication error is detected between the FS control board (FSCB) and the punch control board (PKDB).
  • Causes: Punch control board (PKDB) FS control board (FSCB)
  • Remedy: 1 Disconnect and then connect the power cord. Turn OFF the main power switch, wait for 10 sec. or more, and turn ON the main power switch. 2 Rewrite the firmware. 3 Change PKDB 4 Change FSCB
  • Code: C1004
  • Description: FNS communication error • When the FS control board (FSCB) is receiving data, a communication error is detected.
  • Causes: FS control board (FSCB)
  • Remedy: 1 Disconnect and then connect the power cord. Turn OFF the main power switch, wait for 10 sec. or more, and turn ON the main power switch. 2 Rewrite the firmware. 3 JSCB F1 conduction check 4 JSCB F2 conduction check 5 Change FSCB
  • Code: C1005
  • Description: ZU communication error • When the ZU control board (ZUCB) is receiving data, a communication error is detected.
  • Causes: ZU control board (ZUCB)
  • Remedy: 1 Disconnect and then connect the power cord. Turn OFF the main power switch, wait for 10 sec. or more, and turn ON the main power switch. 2 Rewrite the firmware. 3 Change ZUCB
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us