Description: HDD access error - When correct access to the hard disk kit is failed during access.
Causes: MFP board (MFPB) Hard disk kit (HDD)
Remedy: 1 Reboot the main body. 2 Check the HDD connector for proper connection and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 Change HDD 5 Change MFPB
Code: C051
Display: HDD DISK FULL
Description: HDD full error - Range for user space is full during access to the hard disk kit.
Causes: MFP board (MFPB) Hard disk kit (HDD)
Remedy: 1 Reboot the main body. 2 Delete the job hold in “PROOF/PRINT MENU” to increase the available range for user space. 3 Check the HDD connector for proper connection and correct as necessary. 4 Change H
Code: C052
Display: CARD ERROR
Description: Compact flash access error - When correct access to the compact flash card is failed during access.
Causes: MFP board (MFPB) Compact flash card
Remedy: 1 Reboot the main body. 2 Check the compact flash for proper connection and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 Change compact flash 5 Change MFPB
Code: C053
Display: CARD FULL
Description: Compact flash full error - Range for user space is full during access to the compact flash card.
Causes: MFP board (MFPB) Compact flash card
Remedy: 1 Reboot the main body. 2 Delete the job hold in “PROOF/PRINT MENU” to increase the available range for user space. 3 Check the compact flash for proper connection and correct as necessary. 4 Change compact flash
Code: C054
Display: CARD ERROR
Description: Compact flash disconnected - Compact flash is disconnected
Causes: MFP board (MFPB) Compact flash card
Remedy: 1 Reboot the main body. 2 Check the compact flash for proper connection and correct as necessary. 3 Change compact flash
Code: C060
Display: UPDATE ERROR
Description: Firmware update error - Firmware update fails to complete correctly during update.
Causes: MFP board (MFPB)
Remedy: 1 Reboot the main body. 2 Check the cable that has been used for update of the firmware for proper connection and correct as necessary. 3 Check the firmware update file and if the file is not the correct one, update the firmware again. 4 Check the firmware update procedure and if the procedure is not correct, update the firmware again. 5 Update the firmware again. 6 Check the MFPB connector for proper connection and correct as necessary. 7 Change MFPB