  • Code: P-40
  • Description: Fusing motor torque failure
    When the printing ends, the fusing motor torque exceeds the predetermined value.
  • Causes: • Fusing motor (M3)
    • CPU board (CPUB)
    • Base board (BASEB)
  • Remedy: 1. Check the connector between M3-BASEB CN19E for proper connection and correct as necessary.
    2. Check CPUB for proper installation and correct as necessary.
    3. Replace M3.
    4. Replace CPUB.
    5. Replace BASEB.
  • Code: P-41
  • Description: Machine inside temperature sensor failure
    • After turning ON, when the detected temperature of the paper feed thermistor (TH4) is 10°C and above, the detected temperature of the temperature/humidity sensor (TEM/HUMS) is 0°C.
    • Turning OFF or entry in sleep mode resets the warning.
  • Causes: • Temperature/humidity sensor (TEM/HUMS)
    • CPU board (CPUB)
    • Base board (BASEB)
  • Remedy: 1. Check the connector between TEM/HUMS-BASEB CN15E for proper connection and correct as necessary.
    2. Check CPUB for proper installation and correct as necessary.
    3. Replace the temperature/humidity sensor (TEM/HUMS).
    4. Replace CPUB.
    5. Replace BASEB.
  • Code: P-42
  • Description: PH temperature sensor failure
    • After turning ON, when the detected temperature of the paper feed thermistor (TH4) is 10°C and above, the detected temperature of the PH temperature sensor is 0°C.
    • Turning OFF or entry in sleep mode resets the warning.
  • Causes: • PH unit
    • CPU board (CPUB)
    • Base board (BASEB)
  • Remedy: 1. Check the connector between the PH unit-relay CN308-BASEB CN17E for proper connection and correct as necessary.
    2. Check CPUB for proper installation and correct as necessary.
    3. Replace the PH unit.
    4. Replace CPUB.
    5. Replace BASEB.
  • Code: P-43
  • Description: Paper temperature sensor failure
    • After turning ON, when the detected temperature of the temperature/humidity sensor (TEM/HUMS) is 10°C and above, the detected temperature of the paper feed thermistor (TH4) is 0°C.
    • Turning OFF or entry in sleep mode resets the warning.
  • Causes: • Paper feed thermistor (TH4)
    • CPU board (CPUB)
    • Base board (BASEB)
  • Remedy: 1. Check the connector between TH4-relay CN29-BASEB CN27EA for proper connection and correct as necessary.
    2. Check CPUB for proper installation and correct as necessary.
    3. Replace the paper feed thermistor (TH4).
    4. Replace CPUB.
    5. Replace BASEB.
  • Code: P-5, P-28
  • Description: IDC sensor/Fr failure, IDC sensor/Rr failure
    • During IDC sensor light intensity correction, output voltage detected for all eight sample patterns are 3.35 V or more.
    • During IDC sensor light intensity correction, sensor output voltage for light intensity selected after the correction is under 0.7 V.
    • During IDC base surface detective control, sensor output voltage detected is under 0.7 V or over 3.35V.
    • During image stabilization (gamma correction control), detected output value for IDC sensor did not go below threshold (half the value of what is detected by IDC sensor on the belt surface) for three consecutive times (position of the pattern end is not detected).
    • During image stabilization (gamma correction control), sensor’s output value for hyper 0 gradation after the primary approximation is half the detection level on the belt surface or under.
  • Causes: • IDC sensor/Fr (IDCS/Fr)
    • IDC sensor/Rr (IDCS/Rr)
    • High voltage unit (HV)
    • Transfer belt unit
    • Base board (BASEB)
  • Remedy: 1. Wipe clean the surface of the transfer belt with a soft cloth, if it is dirty.
    2. Replace the transfer belt unit if the transfer belt is damaged.
    3. Reinstall or reconnect IDCS/Fr, connectors connecting between IDCS/Fr-relay CN77-BASEB CN15E, if any of the foregoing parts is installed or connected improperly.
    4. Reinstall or reconnect IDCS/Rr, connectors connecting between IDCS/Rr-relay CN77-BASEB CN15E, if any of the foregoing parts is installed or connected improperly.
    5. Clean IDCS/Fr or IDCS/Rr if it is dirty.
    6. Check the connector between HV CN1-BASEB CN26E for proper connection.
    7. Open/close the front door, run an image stabilization sequence, and select [State Confirmation] -> [Level History 1] to check the IDC value. IDC1: IDCS/Fr IDC2: IDCS/Rr If the value is 1.0 V or less, replace IDCS/Fr or IDCS/Rr.
    8. Replace BASEB.
  • Code: P-9
  • Description: Drum/Development unit (K) failure
    • All density readings taken from the density pattern produced on the transfer belt are 1.0 g/m2 (IDC sensor photo receiver output) or less during max. density adjustment (Vg/Vdc adjustment).
    • All density readings taken from the density pattern produced on the transfer belt are 4.0 g/m2 (IDC sensor photo receiver output) and more during max. density adjustment (Vg/Vdc adjustment).
  • Causes: • Drum unit/K
    • Developing unit/K
    • IDC sensor/Fr (IDCS/Fr)
    • IDC sensor/Rr (IDCS/Rr)
    • Base board (BASEB)
    • High voltage unit (HV)
    • Transfer belt unit
  • Remedy: 1. Check the setting value in [Max Image Density Adj] of [Service Mode] -> [Imaging Process Adjustment] and, if it is negative, readjust.
    2. Check the drive transmission portion of the drum/developing unit and correct as necessary.
    3. Clean the IDC sensor/Fr (IDCS/Fr) or IDC sensor/Rr (IDCS/Rr) window if dirty.
    4. Clean the contact of the drum/developing unit connector if dirty.
    5. Check the connector between HV CN1-BASEB CN26E for proper connection.
    6. Replace the drum unit.
    7. Replace the developing unit.
    8. Replace the transfer belt unit.
    9. Replace HV.
    10. Replace BASEB.