  • Code: C1004
  • Description: FNS communication error (When FS-533, FS-534, FS-534SD or JS-506 is installed) <When FS-533, FS-534 or FS-534SD is installed> • When the FS control board (FSCB) is receiving data, a communication error is detected.
  • Causes: <When FS-533, FS-534 or FS-534SD is installed> • FS control board (FSCB) <When JS-506 is installed> • JS control board (JSCB)
  • Remedy: (a) When FS-533, FS-534 or FS-534SD is installed 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace FSCB. (FS-533/FS-534/FS-534SD) (b) When JS-506 is installed 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace JSCB.
  • Code: C1081
  • Description: SD communication error (When FS-534SD is installed) When a communication error is detected between the FS control board (FSCB) and the SD control board (SDDB).
  • Causes: • SD drive board (SDDB) • FS control board (FSCB)
  • Remedy: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace SDDB. 4. Replace FSCB.
  • Code: C1102
  • Description: Main tray up/down motor drive malfunction (When FS-533, FS-534 or FS-534SD is installed) <When FS-533 is installed> • While the exit tray is being lifted, the paper exit tray home sensor (PS107) is not turned OFF (unblocked) after the set period of time has elapsed after the tray lift up motor (M109) is turned ON. • While the exit tray is being lowered, the paper exit tray home sensor (PS107) is not turned ON (blocked) after the set period of time has elapsed after the tray lift up motor (M109) is turned ON. <When FS-534 or FS-534SD is installed> • While the exit tray is being lifted, the main tray upper position sensor (PS26/PS27) is not turned ON (blocked) and the main tray upper position detect switch (SW2) is not turned ON, even after the main tray up/down motor (M11) turns by the set number of times. • While the exit tray is being lowered, the main tray full detection sensor (PS29) is not turned ON (blocked) after the set period of time has elapsed after the main tray up/down motor (M11) is turned ON.
  • Causes: <When FS-533 is installed> • Tray lift up motor (M109) • Paper exit tray home sensor (PS107) • FS control board (FSCB) <When FS-534 or FS-534SD is installed> • Main tray up/down motor (M11) • Main tray upper position sensor/R (PS26) • Main tray upper position sensor/F (PS27) • Main tray full detection sensor (PS29) • Main tray upper position detect switch (SW2) • FS control board (FSCB)
  • Remedy: (a) When FS-533 is installed 1. Check the connector between M109-FSCB CN108 for proper connection and correct as necessary. 2. Check the connector of M109 for proper drive coupling, and correct as necessary. 3. Check the connector between PS107-FSCB CN110 for proper connection and correct as necessary. 4. PS107 I/O check, sensor check • Control signal: FSCB CN110 • Location of electrical component: FS-533 7-D to E 5. M109 operation check • Control signal: FSCB CN108 • Location of electrical component: FS-533 10-E 6. Replace M109. 7. FSCB CP109 conduction check 8. Replace FSCB. NOTICE • Link to the wiring diagram (N.2.5 FS-533) (b) When FS-534 or FS-534SD is installed 1. Check the motor, sensor and switch connectors for proper connection, and correct as necessary. 2. Check the connector of M11 for proper drive coupling, and correct as necessary. 3. PS26 I/O check, sensor check • Control signal: FSCB J14<A>-5 (ON) • Location of electrical component: FS-534 2-C 4. PS27 I/O check, sensor check • Control signal: FSCB J14<B>-8 (ON) • Location of electrical component: FS-534 3-C 5. PS29 I/O check, sensor check • Control signal: FSCB J14<A>-8 (ON) • Location of electrical component: FS-534 4-C 6. SW2 operation check • Control signal: FSCB J10-1 to 2 • Location of electrical component: FS-534 8-K 7. M11 operation check • Control signal: FSCB J9<A>-9 to 10 • Location of electrical component: FS-534 10-C to D 8. Replace M11. 9. Replace FSCB.
  • Code: C1103
  • Description: Alignment plate motor/Fr malfunction (When FS-533, FS-534 or FS-534SD is installed) <When FS-533 is installed> • The alignment plate home sensor/F (PS108) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. • The alignment plate home sensor/F (PS108) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor/F (M105) is turned ON to return the plate to the home position. <When FS-534 or FS-534SD is installed> • The alignment plate/F home sensor (PS12) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. • The alignment plate/F home sensor (PS12) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor/Front (M7) is turned ON to return the plate to the home position. • The alignment plate/F does not reach the specified position within the set period of time.
  • Causes: <When FS-533 is installed> • Alignment motor/F (M105) • Alignment plate home sensor/F (PS108) • FS control board (FSCB) <When FS-534 or FS-534SD is installed> • Alignment motor/Front (M7) • Alignment plate/F home sensor (PS12) • FS control board (FSCB)
  • Remedy: (a) When FS-533 is installed 1. Check the connector between M105-FSCB CN102 for proper connection and correct as necessary. 2. Check the connector of M105 for proper drive coupling, and correct as necessary. 3. Check the connector between PS108-FSCB CN102 for proper connection and correct as necessary. 4. PS108 I/O check, sensor check • Control signal: FSCB CN102 • Location of electrical component: FS-533 7-J 5. M105 operation check • Control signal: FSCB CN102 • Location of electrical component: FS-533 7-J 6. Replace M105. 7. FSCB CP105 conduction check 8. Replace FSCB. NOTICE • Link to the wiring diagram (N.2.5 FS-533) (b) When FS-534 or FS-534SD is installed 1. Check the connector between M7-FSCB J4 for proper connection and correct as necessary. 2. Check the connector of M7 for proper drive coupling and correct as necessary. 3. Check the connector between PS12-FSCB J4 for proper connection and correct as necessary. 4. PS12 I/O check, sensor check • Control signal: FSCB J4<B>-4 (ON) • Location of electrical component: FS-534 13-C 5. M7 operation check • Control signal: FSCB J4<A>-5 to 8 • Location of electrical component: FS-534 11-C to D 6. Replace M7. 7. Replace FSCB.
  • Code: C1105
  • Description: Bundle eject motor drive malfunction (When FS-534 or FS-534SD is installed) • The gripper home position sensor (PS18) is not turned ON (blocked) even after the set period of time has elapsed after the gripper position detection sensor (PS19) is turned OFF (unblocked). • The gripper position detection sensor (PS19) is not turned OFF (unblocked) even after the set period of time has elapsed after it is turned ON (blocked). • The gripper position detection sensor (PS19) is not turned ON (blocked) even after the set period of time has elapsed after the gripper home position sensor (PS18) is turned OFF (unblocked). • The gripper home position sensor (PS18) is not turned OFF (unblocked) even after the set period of time has elapsed after the bundle eject motor (M10) is energized. • The gripper home position sensor (PS18) and the gripper position detection sensor (PS19) is turned ON (blocked) at the same time.
  • Causes: • Bundle eject motor (M10) • Gripper home position sensor (PS18) • Gripper position detection sensor (PS19) • FS control board (FSCB)
  • Remedy: 1. Check the motor and sensor connectors for proper connection, and correct as necessary. 2. Check the connector of M10 for proper drive coupling, and correct as necessary. 3. PS18 I/O check, sensor check • Control signal: FSCB J13-13 (ON) • Location of electrical component: FS-534 7-C 4. PS19 I/O check, sensor check • Control signal: FSCB J12-3 (ON) • Location of electrical component: FS-534 7-C 5. M10 operation check • Control signal: FSCB J13-1 to 2 • Location of electrical component: FS-534 8-C to D 6. Replace M10. 7. Replace FSCB.
  • Code: C1106
  • Description: Stapler movement motor malfunction (When FS-533, FS-534 or FS-534SD is installed) <When FS-533 is installed> • The stapler home sensor (PS110) is not turned OFF (unblocked) after the laps of given time after it started operating from the home position. • The stapler home sensor (PS110) is not turned ON (blocked) after the laps of give time after the stapler movement motor (M107) turned ON when it returned to the home position. <When FS-534 or FS-534SD is installed> • The stapler home position sensor (Rear) (PS23) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed after the side stapler movement motor (M13) turned ON. • The stapler does not reach the specified position within the set period of time.
  • Causes: <When FS-533 is installed> • Stapler movement motor (M107) • Stapler home sensor (PS110) • Stapler relay board (STREYB) • FS control board (FSCB) <When FS-534 or FS-534SD is installed> • Side stapler movement motor (M13) • Stapler home position sensor (Rear) (PS23) • FS control board (FSCB)
  • Remedy: (a) When FS-533 is installed 1. Check the connector between M107-STREYB CN123 for proper connection, and correct as necessary. 2. Check the connector of M107 for proper drive coupling, and correct as necessary. 3. Check the connector between PS110-FSCB CN110 for proper connection, and correct as necessary. 4. PS110 I/O check, sensor check • Control signal: FSCB CN110 • Location of electrical component: FS-533 8-D to E 5. M107 operation check • Control signal: STREYB CN123-5 to 8 • Location of electrical component: FS-533 5-L 6. Replace M107. 7. Replace STREYB. 8. FSCB CP107 conduction check 9. Replace FSCB. NOTICE • Link to the wiring diagram (N.2.5 FS-533) (b) When FS-534 or FS-534SD is installed 1. Check the connector between M13-relay CN3-FSCB J11 for proper connection, and correct as necessary. 2. Check the connector of M13 for proper drive coupling and correct as necessary. 3. Check the connector between PS23-relay CN3-FSCB J11 for proper connection, and correct as necessary. 4. PS23 I/O check, sensor check • Control signal: FSCB J11<B>-3 (ON) • Location of electrical component: FS-534 4-C 5. M13 operation check • Control signal: FSCB J11<A>-1 to 4 • Location of electrical component: FS-534 4-C to D 6. Replace M13. 7. Replace FSCB.