Description: Bypass Lifting Motion Failure
- The Bypass Lift Sensor (PC29) is not blocked or unblocked even after the set period of time has elapsed after the Bypass Pick-Up Solenoid (SL3) is energized after the manual feed paper take-up operation has begun.
Remedy: 1 Check the SL3 connector for proper connection and correct as necessary. 2 Check cam position.. 3 PC29 I/O check PWB-A. 4 SL3 operation check. 5 Change PWB-A.
Code: C0212
Description: LCT Ejection Failure
- See PC-407 sevice manual
Remedy:
Code: C0213
Description: LCT Shift Gate Malfunction
- See PC-407 sevice manual
Remedy:
Code: C0214
Description: LCT Shifting Failure
- See PC-407 sevice manual
Remedy:
Code: C0215
Description: LCT Shift Motor Malfunction
- See PC-407 sevice manual
Remedy:
Code: C0701
Description: Manual Paper Size Detection Adjustment Failure
- The control value of the Manual Paper Size Detection Unit does not fall within the specified range when an adjustment is made of manual paper size detection.
Remedy: 1 Check the VR1 connector for proper connection and correct as necessary. 2 Readjust the VR1. 3 Replace VR1. 4 Change PWB-A.