  • Code: 0094
  • Description: 2nd Image Transfer Roller Separation
    • The 2nd Image Transfer Pressure Position Sensor doesn’t turn ON (Retracting) even after the lapse of a given period of time after the 2nd Image Transfer Pressure/Retraction Motor has started rotating during the 2nd Image Transfer Roller is retracting. • The 2nd Image Transfer Pressure Position Sensor doesn’t turn OFF (Pressuring) even after the lapse of a given period of time after the 2nd Image Transfer Pressure/Retraction Motor has started rotating during the 2nd Image Transfer Roller is pressuring.
  • Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 Change the Right Door Assy 3 Change PWB-M.
  • Code: 0096
  • Description: Transfer Belt Separation
    • The 1st Image Transfer Pressure/Retraction Position Sensor doesn’t turn ON (Retracting) even after the lapse of a given period of time after the 1st Image Transfer Pressure/Retraction Clutch has turned ON during the Transfer Belt is retracting. • The 1st Image Transfer Pressure/Retraction Position Sensor doesn’t turn OFF (Pressuring) even after the lapse of a given period of time after the 1st Image Transfer Pressure/Retraction Clutch has turned ON during the Transfer Belt is pressuring.
  • Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 PC6 I/O check, Sensor check 3 CL3 operation check PWB-M CNDM1-11 (ON) K to L-2. 4 M1 operation check PWB-M CNDM1-5 (REM) PWB-M CNDM1-8 (LOCK) K to L-2. 5 Change PWB-M.
  • Code: 0301
  • Description: Polygon Motor/C failure to turn
    • The Polygon motor fails to turn stably even after the lapse of a given period of time after activating the Polygon motor. • Motor Lock signal detects H for a given period time consecutively during the Polygon motor is rotating.
  • Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-D. 4 Change PWB-M7.
  • Code: 0302
  • Description: Polygon Motor/M failure to turn
    • The Polygon motor fails to turn stably even after the lapse of a given period of time after activating the Polygon motor. • Motor Lock signal detects H for a given period time consecutively during the Polygon motor is rotating.
  • Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-D. 4 Change PWB-M7.
  • Code: 0303
  • Description: Polygon Motor/Y failure to turn
    • The Polygon motor fails to turn stably even after the lapse of a given period of time after activating the Polygon motor. • Motor Lock signal detects H for a given period time consecutively during the Polygon motor is rotating.
  • Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-D. 4 Change PWB-M7.
  • Code: 0304
  • Description: Polygon Motor/K failure to turn
    • The Polygon motor fails to turn stably even after the lapse of a given period of time after activating the Polygon motor. • Motor Lock signal detects H for a given period time consecutively during the Polygon motor is rotating.
  • Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-D. 4 Change PWB-M7.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us