PrintCopy.info service

Konica-Minolta Magicolor 2400W

Error Codes List page 3

  • Code: 19H
  • Description: Abnormally low Heating Roller temperature
    • The temperature detected by the Thermistor remains lower than a predetermined value for a predetermined period of time.
  • Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PU, and PWB-A for proper connection and correct as necessary. 3 Check the lever of the Safety Switch and correct as necessary. 4 Change the Fusing Unit. 5 Change PWB-A. 6 Change PU.
  • Code: 1AH
  • Description: Abnormally high Heating Roller temperature
    • The temperature detected by the Thermistor is a predetermined value or higher for a predetermined period of time.
  • Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PU, and PWB-A for proper connection and correct as necessary. 3 Check the lever of the Safety Switch and correct as necessary. 4 Change the Fusing Unit. 5 Change PWB-A. 6 Change PU.
  • Code: 1BH
  • Description: Faulty Thermistor
    • The condition of a temperature rise of less than 1°C extends continuously for a predetermined period of time that begins when the warm-up cycle is started.
  • Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PU, and PWB-A for proper connection and correct as necessary. 3 Check the lever of the Safety Switch and correct as necessary. 4 Change the Fusing Unit. 5 Change PWB-A. 6 Change PU.
  • Code: 21H
  • Description: Faulty OHP Sensor
    • It is determined that the OHP Sensor is faulty through a check made at the end of the predrive.
  • Remedy: 1 Check the PWB-A connector for proper connection and correct as necessary. 2 PC2A sensor check. PWB-A PJ12A-6 (ON) 2-D. 3 Change PWB-A.
  • Code: 23H
  • Description: Faulty Waste Toner Near Full Detection Board
    • It is determined that the LED and photoreceiver are faulty through a check made when a new Drum Cartridge is detected.
  • Remedy: 1 Check the PWB-C connector for proper connection and correct as necessary. 2 Check the PWB-A connector for proper connection and correct as necessary. 3 Change the Drum Cartridge. 4 Change PWB-C. 5 Change PWB-A.
  • Code: 24H
  • Description: Faulty Fusing Thermistor Resistor
    • The Heater Lamp remains ON for a predetermined consecutive period of time.
  • Remedy: