  • Code: E7
  • Description: Pocket Door Error (Switch Abnormal)
  • Causes: Both the Open Sensing Switch and the Close Sensing Switch detect “0” while the Pocket Door is moving.
  • Remedy: Pocket Door Part Turn off the machine. Rotate the Pocket Door Motor manually. Does the Pocket Door move smoothly? No 1. Check if the Rack Gear is overrun. 2. Check if the Lever of the Swing Plate comes off the Rack Gear. 3. Check if the Warm Gear and the Motor Output Spindle are fixed properly.
    Pocket Door Switch Turn off the machine, and rotate the Warm Gear manually. Are S19-1 and S19-2 the following status when the Pocket Door is closed? S19-1: OFF S19-2: ON Are S19-1 and S19-2 the following status when the Pocket Door is opened? S19-1: ON S19-2: OFF No Check the wiring between J19 to the Pocket Door Switch. If there is no problem, replace the Pocket Door Switch with the new one.
    Pocket Door Motor Enter the Service Mode and select the Output Test 2 of the Function Checking Mode. (Refer to the page 8-31.) Does the voltage between the CN104-4 and CN104-5 on the Control PCB (PW10620) change momentarily (within 2 seconds)? <Note> The Polarity of the voltage (0 to 12V) is inverted depending on the condition of the Pocket Door (open/close). No Check the wiring between CN104 and Pocket Door Motor. If there is no problem, replace the Pocket Door Motor or the Control PCB (PW10620) with the new one.
  • Code: E9
  • Description: Exposure Lamp Error (Dark)
  • Causes: The light intensity of the Exposure Lamp is less than the specified amount.
  • Remedy: EXP Lamp (FL1) Turn off the machine. Is the EXP Lamp (FL1) connected with the EXP Lamp Socket properly? Are the connectors connect properly? No Connect properly. Is the side of the EXP Lamp burnt to black? Yes Replace the EXP Lamp with the new one.
    EXP Sensor PCB Can you fix the problem when you replace the EXP Sensor PCB with new one? Yes OK.
    EXP. Power Supply PCB Is the voltage between J24-1-1(+) and J24-1-2 (-) on the EXP. Power Supply PCB 24V during the Ready condition? No Replace the EXP. Power Supply PCB with the new one.
  • Code: EA
  • Description: Exposure Lamp Error (Bright)
  • Causes: The light intensity of the Exposure Lamp is more than the specified amount.
  • Remedy: EXP Lamp (FL1) Turn off the machine. Is the EXP Lamp (FL1) connected with the EXP Lamp Socket properly? Are the connectors connect properly? No Connect properly. Is the side of the EXP Lamp burnt to black? Yes Replace the EXP Lamp with the new one.
    EXP Sensor PCB Can you fix the problem when you replace the EXP Sensor PCB with new one? Yes OK.
    EXP. Power Supply PCB Is the voltage between J24-1-1(+) and J24-1-2 (-) on the EXP. Power Supply PCB 24V during the Ready condition? No Replace the EXP. Power Supply PCB with the new one.
  • Code: EC
  • Description: Counter Error
  • Causes: 1. The Counter is not inserted to the machine when the machine is turned on. 2. The Counter is defective.
  • Remedy: Counter (CNT) Is the Counter (CNT) connected properly? No Connect properly.
    Counter (CNT) Control PCB (PW10620) Enter the Service Mode and select the Output Test 2 of the Function Checking Mode. (Refer to the page 8-31.) Does the voltage between CN209-1 and CN209-2 on the Control PCB (PW10620) change momentarily? No Replace the Counter (CNT) or the Control PCB (PW10620) with the new one.
  • Code: ED
  • Description: Developer Motor Error
  • Causes: LD Signal is detected for 1 seconds continuously while the Developer Motor is rotating.
  • Remedy: Developer Motor Are the connectors connect with the Developer Motor properly? No Connect properly.
    Control PCB (PW10620) Enter the Service Mode and select the Manual Charging Test of the Function Checking Mode. (Refer to the page 8-24.) 1. Does the voltage between the CN106-4 (+) and CN106-6 (-) on the Control PCB (PW10620) change to about 6V to 0V when the Developer Motor rotates? 2. Is the voltage between CN211-4 (+) and CN211-1 (-) on the Control PCB (PW10620) about 24V during the Ready condition? No Replace the Control PCB (PW10620) with the new one.
    Developer Motor Motor Control PCB Replace the Developer Motor or the Motor Control PCB with the new one.
  • Code: EE
  • Description: Main Motor Error
  • Causes: LD Signal is detected for 1 seconds continuously while the Main Motor is rotating.
  • Remedy: Main Motor (M1) Are the connectors connect with the Main Motor (M1) properly? No Connect properly.
    Control PCB (PW10620) Enter the Service Mode and select the Output Test 1 of the Function Checking Mode. (Refer to the page 8-28.) Make the Main Motor work. 1. Does the voltage between CN106-2 (+) and CN106-6 (-) on the Control PCB (PW10620) change to about 6V to 0V when the Main Motor rotates? 2. Is the voltage between CN211-4 (+) and CN211-1 (-) on the Control PCB (PW10620) about 24V during the Ready condition? No Replace the Control PCB (PW10620) with the new one.
    Main Motor (M1) Motor Control PCB Replace the Main Motor (M1) or the Motor Control PCB with the new one.