Remedy: 1 Have you removed all jammed sheets in the media path? No Clear the media path. Status 2 Sensor status is detected correctly. “H” = Paper Detected “L” =Paper Absence Yes OK No Check the actuator’s smooth motion. Sensor 3 Replacing relevant sensor recovers Jam Status. Upper Exit Sensor (PH91) Yes OK PW13555 4 Replacing PW13555 recovers Jam Status. Yes OK Main Control PCB (PW13520) 5 Replacing PW13520 PCB recovers Jam Status. Yes OK
Remedy: Toner Cartridge 1 Is the seal on the Toner Cartridge removed? Does the supply hole on the Toner Cartridge come downward? No Remove the seal. Turn the bottle down properly. Main Control PCB (PW13520) 2 Can the problem be fixed by replacing the Main Control PCB? Yes OK
Remedy: Roll Media Spool 1 Is the roll media set on the spool correctly? Is the spool loaded to the machine correctly? No Set it correctly. Main Control PCB (PW13520) 2 Can the problem be fixed by replacing the Main Control PCB? Yes OK
Remedy: Waste Toner Box 1 Is the Waste Toner Box filled with the toner? Is it set correctly? Yes Replace Waste Toner Box. Reseat it. Main Control PCB (PW13520) 2 Can the problem be fixed by replacing the Main Control PCB? Yes OK
Code: U-00000002
Description: Deck 1 Open
Causes: Input Check Mode No. 00411 Deck1 Status (“H” = Open
Remedy: Status 1 Deck1 Status is detected correctly. “H” = Deck Open / “L” = Deck Closed Yes OK Deck Switch Upper SW10-1 2 Voltage between SW10-1 Tub1 and Frame-GND is 5V DC when Deck is Opened. Voltage between SW10-1 Tub1 and Frame-GND is 0V DC when Deck is Closed. Voltage between SW10-1 Tub3 and Frame-GND is always 0V DC. No In Case Status detection is still incorrect replace SW10-1. PW13555 3 Voltage between J565-25 and Frame- GND is 5V DC when Deck is Opened. Voltage between J565-25 and Frame- GND is 0V DC when Deck is Closed. Voltage between J565-26 and Frame- GND is always 0V DC. Yes In Case Status detection is still incorrect replace PW13555 PW13555 4 Replacing PW13555 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 5 Replacing PW13520 PCB recovers the error condition. Yes OK
Remedy: Status 1 Deck2 Status is detected correctly. “H” = Deck Open / “L” = Deck Closed Yes OK Deck Switch Upper SW10-2 2 Voltage between SW10-2 Tub1 and Frame-GND is 5V DC when Deck is Opened. Voltage between SW10-2 Tub1 and Frame-GND is 0V DC when Deck is Closed. Voltage between SW10-2 Tub3 and Frame-GND is always 0V DC. No In Case Status detection is still incorrect replace SW10-2. PW13555 3 Voltage between J565-27 and Frame- GND is 5V DC when Deck is Opened. Voltage between J565-27 and Frame- GND is 0V DC when Deck is Closed. Voltage between J565-28 and Frame- GND is always 0V DC. Yes In Case Status detection is still incorrect replace PW13555 PW13555 4 Replacing PW13555 PCB recovers Door Status. Yes OK Main Control PCB (PW13520) 5 Replacing PW13520 PCB recovers Door Status. Yes OK