Description: High Voltage Board 1 Communication Error
Causes: Failed to receive Completed Status from FPGA on PW13555 after “High Voltage Control Data” Read or Write Command has been sent to the “High Voltage Section on PW13555”.
Remedy: Error Mask Mode No. 00706 HV Bord1 Error Wiring Harness 1 Following connectors are surely connected. J214 on PW13520 and J567 on PW13555 No Plug the Connector. PW13555 2 Replacing PW13555 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 3 Replacing PW13520 PCB recovers the error condition. Yes OK
Code: E-0A05, E-2565
Description: High Voltage Board 2 Communication Error
Causes: Failed to receive Completed Status from FPGA on PW13555 after “High Voltage Control Data” Read or Write Command has been sent to “PW13556 High Voltage Board 2”.
Remedy: Error Mask Mode No. 00707 HV Bord2 Error Wiring Harness 1 Following connectors are surely connected. J573 on PW13555, J561 on PW13556, J214 on PW13520 and J567 on PW13555 No Plug the Connector. PW13556 2 Replacing PW13556 PCB recovers the error condition. Yes OK PW13555 3 Replacing PW13555 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 4 Replacing PW13520 PCB recovers the error condition. Yes OK
Code: E-0A41, E-2625
Description: KNC1 Error
Causes: KNC1 Error occurs.
Remedy: Wiring Harness 1 Following connectors are surely connected. J267 on PW13551 and J215 on PW13520 No Plug the Connector. PW13551 2 Replacing PW13551 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 3 Replacing PW13520 PCB recovers the error condition. Yes OK
Code: E-0A42, E-2626
Description: KNC2 Error
Causes: KNC2 Error occurs.
Remedy: Wiring Harness 1 Following connectors are surely connected. J267 on PW13551 and J215 on PW13520 No Plug the Connector. PW13551 2 Replacing PW13551 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 3 Replacing PW13520 PCB recovers the error condition. Yes OK
Code: E-0A43, E-2627
Description: KNC3 Error
Causes: KNC3 Error occurs.
Remedy: Wiring Harness 1 Following connectors are surely connected. J267 on PW13551 and J215 on PW13520 No Plug the Connector. PW13551 2 Replacing PW13551 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 3 Replacing PW13520 PCB recovers the error condition. Yes OK
Code: E-0A44, E-2628
Description: KNC4 Error
Causes: KNC4 Error occurs.
Remedy: Wiring Harness 1 Following connectors are surely connected. J267 on PW13551 and J215 on PW13520 No Plug the Connector. PW13551 2 Replacing PW13551 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 3 Replacing PW13520 PCB recovers the error condition. Yes OK