Description: ADC Test Failure in the Main PCA A short circuit in the Y/X-axis or ANY stepper motor. This short circuit is causing some of the fuses in the Electronics Module to burn. Error data: 00000800 -Problem with the Y-axis. 00001000 -Problem with the X-axis.
Code: 010037
Description: ADC Test Failure in the Carriage PCA.
Code: 010038
Description: A Printhead voltage could not be set -Main PCA Failure.
Code: 010039
Description: A Printhead voltage could not be set -Carriage PCA Failure
Code: 010040
Description: The Ambient Temperature measured is out of the normal range.
Code: 010042
Description: The status of one of the opticalsensors is not stable when it should be. Error data (X): 0 -Problem with the Media Sensor. 1 -Problem with the Pinch-arm Sensor. 2 -Problem with the Refill Assembly Sensor. 3 -Problem with the Elevator Sensor. 4 -Problem with the Service Station Sensor. 5 -Problem with the Primer Sensor.