PrintCopy.info service

HP Color LaserJet Pro M452

Error Codes List page 2

  • Code: 50.10
  • Display: 50.XX Fuser Error, Turn off then on
  • Description: The product has experienced an internal fuser hardware error
  • Causes: Low Fuser temperature error
  • Remedy: 1. Reset the product:a. Turn off the power by using the power switch, and then wait at least 30 seconds.b. Turn on the power and wait for the product to initialize.2. If you are using a surge protector:a. Power off the product.b. Remove the surge protector.c. Plug the product directly into the wall socket and turn the product power on.3. If the error persists, replace the Fusing Assembly: Fusing Assembly, 110 VAC, simplex models (HP Part #: RM2–6431–000CN Fusing Assembly, 220 VAC, simplex models (HP Part #: RM2–6436–000CN Fusing Assembly, 110 VAC, duplex models (HP Part #: RM2–6418–000CN Fusing Assembly, 220 VAC, duplex models (HP Part #: RM2–6435–000CN4. If the error persists, replace the product.
  • Code: 50.11
  • Display: 50.XX Fuser Error, Turn off then on
  • Description: The product has experienced an internal fuser hardware error
  • Causes: High sub thermistor area 3 fuser error
  • Remedy: 1. Reset the product:a. Turn off the power by using the power switch, and then wait at least 30 seconds.b. Turn on the power and wait for the product to initialize.2. If you are using a surge protector:a. Power off the product.b. Remove the surge protector.c. Plug the product directly into the wall socket and turn the product power on.3. If the error persists, replace the Fusing Assembly: Fusing Assembly, 110 VAC, simplex models (HP Part #: RM2–6431–000CN Fusing Assembly, 220 VAC, simplex models (HP Part #: RM2–6436–000CN Fusing Assembly, 110 VAC, duplex models (HP Part #: RM2–6418–000CN Fusing Assembly, 220 VAC, duplex models (HP Part #: RM2–6435–000CN4. If the error persists, replace the product.
  • Code: 50.12
  • Display: 50.XX Fuser Error, Turn off then on
  • Description: The product has experienced an internal fuser hardware error
  • Causes: Low sub thermistor area 3 fuser error
  • Remedy: 1. Reset the product:a. Turn off the power by using the power switch, and then wait at least 30 seconds.b. Turn on the power and wait for the product to initialize.2. If you are using a surge protector:a. Power off the product.b. Remove the surge protector.c. Plug the product directly into the wall socket and turn the product power on.3. If the error persists, replace the Fusing Assembly: Fusing Assembly, 110 VAC, simplex models (HP Part #: RM2–6431–000CN Fusing Assembly, 220 VAC, simplex models (HP Part #: RM2–6436–000CN Fusing Assembly, 110 VAC, duplex models (HP Part #: RM2–6418–000CN Fusing Assembly, 220 VAC, duplex models (HP Part #: RM2–6435–000CN4. If the error persists, replace the product.
  • Code: 50.20
  • Display: 50.XX Fuser Error, Turn off then on
  • Description: The product has experienced an internal fuser hardware error
  • Causes: Slow fuser error
  • Remedy: 1. Reset the product:a. Turn off the power by using the power switch, and then wait at least 30 seconds.b. Turn on the power and wait for the product to initialize.2. If you are using a surge protector:a. Power off the product.b. Remove the surge protector.c. Plug the product directly into the wall socket and turn the product power on.3. If the error persists, replace the Fusing Assembly: Fusing Assembly, 110 VAC, simplex models (HP Part #: RM2–6431–000CN Fusing Assembly, 220 VAC, simplex models (HP Part #: RM2–6436–000CN Fusing Assembly, 110 VAC, duplex models (HP Part #: RM2–6418–000CN Fusing Assembly, 220 VAC, duplex models (HP Part #: RM2–6435–000CN4. If the error persists, replace the product.
  • Code: 50.30
  • Display: 50.XX Fuser Error, Turn off then on
  • Description: The product has experienced an internal fuser hardware error
  • Causes: High fuser temperature error
  • Remedy: 1. Reset the product:a. Turn off the power by using the power switch, and then wait at least 30 seconds.b. Turn on the power and wait for the product to initialize.2. If you are using a surge protector:a. Power off the product.b. Remove the surge protector.c. Plug the product directly into the wall socket and turn the product power on.3. If the error persists, replace the Fusing Assembly: Fusing Assembly, 110 VAC, simplex models (HP Part #: RM2–6431–000CN Fusing Assembly, 220 VAC, simplex models (HP Part #: RM2–6436–000CN Fusing Assembly, 110 VAC, duplex models (HP Part #: RM2–6418–000CN Fusing Assembly, 220 VAC, duplex models (HP Part #: RM2–6435–000CN4. If the error persists, replace the product.
  • Code: 50.40
  • Display: 50.XX Fuser Error, Turn off then on
  • Description: The product has experienced an internal fuser hardware error
  • Causes: Fuser drive circuit error
  • Remedy: 1. Reset the product:a. Turn off the power by using the power switch, and then wait at least 30 seconds.b. Turn on the power and wait for the product to initialize.2. If you are using a surge protector:a. Power off the product.b. Remove the surge protector.c. Plug the product directly into the wall socket and turn the product power on.3. If the error persists, replace the Fusing Assembly: Fusing Assembly, 110 VAC, simplex models (HP Part #: RM2–6431–000CN Fusing Assembly, 220 VAC, simplex models (HP Part #: RM2–6436–000CN Fusing Assembly, 110 VAC, duplex models (HP Part #: RM2–6418–000CN Fusing Assembly, 220 VAC, duplex models (HP Part #: RM2–6435–000CN4. If the error persists, replace the product.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files