  • Code: 1005
  • Description: 24V controller FAN lock error
  • Causes: Cooling Fan (+24V) is not rotating.
  • Remedy: 1. Check the connection between the Cooling Fan (+24V) and Main Board (CN24).
    2. Check if the Cooling Fan (+24V) is not distorted.
    1. Connect the Cooling Fan (+24V) again.
    2. Replace the Cooling Fan (+24V) with a new one.
  • Code: 1102
  • Description: Tube maintenance error
    The maintenance counter of the Ink Supply Tube exceeds the threshold value. (CR Unit drive path count exceeds the specified value (21 million passes).)
  • Causes:
  • Remedy: Replace the Printer with a new one.
  • Code: 1125
  • Description: CR HP detection error
  • Causes: The CR Unit cannot track the Home position to set the CR origin.
    • False origin detection due to paper jam or the like
    • Misreading of CR Scale
    • CR Lock failure
  • Remedy: 1. Check if the paper is jammed.
    2. Check if the CR Scale is read out properly. • Check if the CR Scale is damaged or contaminated.
    3. Check if the CR Lock functions normally.
    1. Re-install the CR Unit.
    2. Clean the CR Scale with ethanol.
    3. Replace the CR Scale with a new one.
    4. Replace the Capping Unit with a new one.
  • Code: 1126
  • Description: CR lock set error
    CR lock set release error
  • Causes: Capping Unit operation in abnormal.
    • Motor failure
    • Cable is damaged.
    • Board is damaged.
    • Capping Unit failure
  • Remedy: 1. Check the connection between the Capping Unit and Main Board (CN203).
    2. Unlock the CR Lock and check if the CR Lock functions normally.
    1. Replace the Capping Unit with a new one.
    2. Replace the Main Board with a new one.
  • Code: 1127
  • Description: Overcurrent error
  • Causes: The electric current flowing in the CR Unit exceeds the expected amount.
    • Irregular load due to paper jam.
    • Motor Lock
    • Motor driver failure
    • Encoder sensor failure
  • Remedy: Check if there are any foreign objects in the path of the CR Unit.
    • Remove the foreign objects in the path if any.
    • Error reoccurs • Replace the CR Motor with a new one. • Replace the Main Board with a new one. • Replace the CR Unit with a new one.
  • Code: 1138
  • Description: CR Motor over current error
  • Causes: 1. Connection failure of the CR Motor or the CR encoder sensor.
    2. Detects accumulatively more than the specified number of times that the electric current which flows when driving the CR Motor is irregularly large. • Irregular load • Sensor failure
  • Remedy: 1. Check the connection between the CR encoder sensor and Main Board (CN100).
    2. Check the connection between the CR Motor and Main Board (CN200).
    1. Replace the CR Unit with a new one.
    2. Replace the CR Motor with a new one.
    3. Replace the Printer with a new one.