PrintCopy.info service

Epson SC-T3400

Error Codes List page 2

  • Code: 001138
  • Description: CR Motor Overcurrent Error
    The number of occurrences of overcurrent to the CR Motor has reached a predetermined limit.
  • Causes: • CR Motor failure
    • CR Belt state abnormality (tension, installation position)
    • CR Motor cable abnormality (connection, broken)
    • Misreading of CR Scale (scratch, dirt)
    Parts/Components to be checked
    1. CR Motor
    2. CR Belt
    3. CR Scale
    4. CR Encoder
    5. Main Board
    6. Sub Board B
  • Remedy: 1 Check the CR Motor operation state • When the CR Motor is malfunctioning, replace it. Does the product recover from the error?
    Y: End
    N: Go to step 2
    2 Check the CR Belt state • Check if the CR Belt is installed properly. If not, install it again. • Check if the CR Belt tension is in the standard range. If not, perform CR Timing Belt Tension Adjustment. Does the product recover from the error?
    Y: End
    N: Go to step 3
    3 Check the CR Motor cable connection • Check the CR Motor connection state. If there is any abnormality, connect it again. Does the product recover from the error?
    Y: End
    N: Go to step 4
    4 Check the CR Scale state • Check visually if the CR Scale have any scratches or dirt. ƒß When the CR Scale is dirty: clean it. ƒß When there is a scratch on the CR Scale: replace it. Does the product recover from the error?
    Y: End
    N: Go to step 5
    5 Replace the Encoder Board Does the product recover from the error?
    Y: End
    N: Go to step
    6 Replace the Main Board Does the product recover from the error?
    Y: End
    N: Go to step 7
    7 Replace the Sub Board B Does the product recover from the error?
    Y: End
    N: Escalate to person in charge
  • Code: 001139
  • Description: CR Motor Oscillation Error
    The number of oscillations exceeds the specified value.
  • Causes: • Main Board failure
    • Sub Board B failure
    Parts/Components to be checked
    1. Main Board
    2. Sub Board B
    3. CR Motor
  • Remedy: 1 Check the Main Board state • Check if any foreign object is on the Main Board. If so, remove it. Does the product recover from the error?
    Y: End
    N: Go to step 2
    2 Check the Sub Board B state • Check if any foreign object is on the Sub Board B. If so, remove it. Does the product recover from the error?
    Y: End
    N: Go to step 3
    3 Replace the Main Board Does the product recover from the error?
    Y: End
    N: Go to step 4
    4 Replace the Sub Board B Does the product recover from the error?
    Y: End
    N: Go to step 5
    5 Replace the CR Motor Does the product recover from the error?
    Y: End
    N: Escalate to person in charge
  • Code: 00113A
  • Description: CR Motor Overload Error
    Overcurrent is detected more than predetermined limit since the CR Motor did not operate properly because of some kind of load.
  • Causes: • Load abnormality
    • CR Encoder cable abnormality (connection, broken)
    • CR Motor cable abnormality (connection, broken)
    • CR Encoder failure
    • CR Motor failure
    Parts/Components to be checked
    1. CR Unit
    2. CR Encoder
    3. CR Motor
  • Remedy: 1 Check the obstacle in the carriage moving range • Check if any obstacle is blocking the carriage movement. If so, remove the obstacle. Does the product recover from the error?
    Y: End
    N: Go to step 2
    2 Checking the CR Unit state • Check if the CR Unit is installed properly. If not, install it again. Does the product recover from the error?
    Y: End
    N: Go to step 3
    3 Check the Encoder Board and CR Sub Board cable connection • Check both Encoder Board and CR Sub Board connection state. If there is any abnormality, connect it again. Does the product recover from the error?
    Y: End
    N: Go to step 4
    4 Check the CR Motor cable connection • Check the CR Motor connection state. If there is any abnormality, connect it again. Does the product recover from the error?
    Y: End
    N: Go to step 5
    5 Lubrication to the Oil Pad Does the product recover from the error?
    Y: End
    N: Go to step 6
    6 Replace the Encoder Board Does the product recover from the error?
    Y: End
    N: Go to step 7
    7 Replace the CR Motor Does the product recover from the error?
    Y: End
    N: Escalate to person in charge
  • Code: 00113C
  • Description: CR Motor Reversing Error
    The number of occurrences of reversing the CR Motor has reached a predetermined limit.
  • Causes: • CR Encoder cable abnormality (polarity reversal)
    • CR Motor cable abnormality (polarity reversal)
    • Slipping of the teeth of the CR Belt
    • CR Encoder failure
    Parts/Components to be checked
    1. CR Belt
    2. CR Encoder
  • Remedy: 1 Check the Encoder Board and CR Sub Board cable connection • Check both Encoder Board and CR Sub Board connection state. If there is any abnormality, connect it again. Does the product recover from the error?
    Y: End
    N: Go to step 2
    2 Check the CR Motor cable connection • Check the CR Motor connection state. If there is any abnormality, connect it again. Does the product recover from the error?
    Y: End
    N: Go to step 3
    3 Check the CR Belt state • Check if the CR Belt is installed properly. If not, install it again. • Check if the CR Belt tension is in the standard range. If not, perform CR Timing Belt Tension Adjustment. Does the product recover from the error?
    Y: End
    N: Go to step 4
    4 Replace the CR Encoder Does the product recover from the error?
    Y: End
    N: Escalate to person in charge
  • Code: 00113D
  • Description: CR Motor Driving time-out Error
    Abnormally-long driving duration of the CR Motor was detected.
  • Causes: • Load abnormality
    • Firmware becomes out of control
    Parts/Components to be checked
    1. Main Board
    2. Sub Board B
  • Remedy: 1 Update the F/W Does the product recover from the error?
    Y: End
    N: Go to step 2
    2 Replace the Main Board Does the product recover from the error?
    Y: End
    N: Go to step 3
    3 Replace the Sub Board B Does the product recover from the error?
    Y: End
    N: Escalate to person in charge
  • Code: 00113E
  • Description: CR Motor Velocity Deviation Error
    The CR Motor was driven at a speed abnormally faster than a predetermined one during acceleration or deceleration.
  • Causes: • Load abnormality
    • CR Encoder failure
    • CR Motor failure
    • CR Sub Board failure
    • Main Board failure
    • Sub Board B failure
    Parts/Components to be checked
    1. CR Encoder
    2. CR Motor
    3. CR Sub Board
    4. Main Board
    5. Sub Board B
  • Remedy: 1 Replace the CR Encoder Does the product recover from the error?
    Y: End
    N: Go to step 2
    2 Replace the CR Motor Does the product recover from the error?
    Y: End
    N: Go to step 3
    3 Replace the CR Sub Board Does the product recover from the error?
    Y: End
    N: Go to step 4
    4 Replace the Main Board Does the product recover from the error?
    Y: End
    N: Go to step 5
    5 Replace the Sub Board B Does the product recover from the error?
    Y: End
    N: Escalate to person in charge