PrintCopy.info service

Epson AcuLaser CX28DN

Error Codes List page 2

  • Code: 004A
  • Description: Duplex cooling fan motor malfunction
    - The duplex cooling fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
    - The motor lock signal remains HIGH for a given period of consecutive time while the duplex cooling fan motor is being rotated.
  • Causes: Duplex cooling fan motor (FM4) Print control board (PRCB)
  • Remedy: 1 Check the FM4 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM4 operation check PRCB PJ27-6 (LOCK) C to D-4 4 Change FM4. 5 Change PRCB.
  • Code: 004C
  • Description: Ozone ventilation fan motor malfunction
    - The ozone ventilation fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
    - The motor lock signal remains HIGH for a given period of consecutive time while the ozone ventilation fan motor is being rotated.
  • Causes: Ozone ventilation fan motor (FM3) Print control board (PRCB)
  • Remedy: 1 Check the FM3 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM3 operation check PRCB PJ31-3 (LOCK) C to D-15 4 Change FM3. 5 Change PRCB.
  • Code: 004E
  • Description: DC power supply fan motor malfunction
    - The DC power supply fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
    - The motor lock signal remains HIGH for a given period of consecutive time while the DC power supply fan motor is being rotated.
  • Causes: DC power supply fan motor (FM1) Print control board (PRCB)
  • Remedy: 1 Check the FM1 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM1 operation check PRCB PJ34-3 (LOCK) C to D-14 4 Change FM1. 5 Change PRCB.
  • Code: 0060
  • Description: Fusing motor malfunction
    - The fusing motor does not rotate evenly even after the lapse of a given period of time while it is being started.
    - The motor lock signal remains HIGH for a given period of consecutive time while the fusing motor is being rotated.
  • Causes: Fusing motor (M4) Print control board (PRCB)
  • Remedy: 1 Check the M4 connector for proper connection and correct as necessary. 2 Check the fuser unit driving mechanism for possible overload and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M4 operation check PRCB PJ19-3 to 9 L-4 5 Change M4. 6 Change PRCB.
  • Code: 0094
  • Description: 2nd image transfer pressure / retraction failure
    - The 2nd image transfer retraction position sensor is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd transfer roller has been started.
    - The 2nd image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd transfer roller has been started.
  • Causes: 2nd image transfer retraction position sensor (PS10) 2nd image transfer pressure/retraction clutch (CL5) Transport motor (M3) Print control board (PRCB)
  • Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL5 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL5 for proper drive coupling and correct as necessary. 5 Check the PRCB connector for proper connection and correct as necessary. 6 PS10 sensor check PRCB PJ16-8 (ON) C to D-5 7 CL5 operation check PRCB PJ10-5 (REM) C to D-7 to 8 8 M3 operation check PRCB PJ11-1 to 7 L-4 9 Change M3. 10 Change CL5. 11 Change PRCB.
  • Code: 0096
  • Description: 1st image transfer pressure / retraction failure
    - The 1st image transfer retraction position sensor is not activated (retracted position) within a given period of time after the intermediate transport motor has started rotating.
    - The 1st image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the intermediate transport motor has started rotating.
  • Causes: 1st image transfer retraction position sensor (PS9) 1st image transfer pressure/retraction clutch (CL4) Transport motor (M3) Print control board (PRCB)
  • Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL4 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL4 for proper drive coupling and correct as necessary. 5 Check the PRCB connector for proper connection and correct as necessary. 6 PS9 sensor check PRCB PJ7-11 (ON) L-6 7 CL4 operation check PRCB PJ19-2 (REM) L-4 to 5 8 M3 operation check PRCB PJ11-1 to 7 L-4 9 Change M3. 10 Change CL4. 11 Change PRCB.