PrintCopy.info service

Epson AcuLaser C8600

Error Codes List page 3

  • Code: 1400
  • Description: Engine initialization malfunction
  • Remedy: 1 • Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2 2 • Initializing the MCU PWB: • By using the DIAG command, execute “Slave Initialize”. Turn the power off once and on again. Does the printer operate normally? Problem solved Go to step 3 3 • Replacing the relevant unit: • Replace the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved
  • Code: 1500
  • Description: CCNV hardware error
  • Remedy: 1 • Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2 2 • Replacing the IC concerned: • Replace IC603 for AcuLaser C8600 or IC600 for AcuLaser C7000 (VIPS: E05B93BA) • Replace IC602 for AcuLaser C8600 or IC601 for AcuLaser C7000 In cases other than above, replace the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved
  • Code: 1550
  • Description: Compression SRAM initialization hardware error
  • Remedy: 1 • Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2 2 • Checking the SD-RAM: • Remove all SD-RAMs from the RAM slots and then reinsert them in the RAM slots. Be sure to insert the SD-RAMs one by one (S0 and S1) in order so that the SD-RAM error can be identified. Every time you insert an SD-RAM, follow the procedures below and repeat it for each one. 1 Turn the power off. 2 Add the SD-RAM. 3 Turn the power on. • Insert the SD-RAM in the socket until it is locked securely. NOTE: Since the SD-RAM has the right direction to insert, be sure to insert it in the correct direction. Replace or reinstall the relevant part. Go to step 3 3 • Replacing the IC concerned: • Replace IC603 for AcuLaser C8600 or IC600 for AcuLaser C7000 (VIPS: E05B93BA) • Replace IC602 for AcuLaser C8600 or IC601 for AcuLaser C7000 In cases other than above, replace the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved
  • Code: 1600
  • Description: Video related hardware error (including PWM IC calibration error)
  • Remedy: 1 • Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2 2 • Replacing the IC concerned: • Replace IC603 for AcuLaser C8600 or IC600 for AcuLaser C7000 (VIPS: E05B93BA) • Replace IC602 for AcuLaser C8600 or IC601 for AcuLaser C7000 In cases other than above, replace the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved
  • Code: 1999
  • Description: Other hardware error
  • Remedy: 1 • Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2 2 • Initializing the MCU PWB: • By using the DIAG command, execute “Slave Initialize”. Turn the power off once and on again. Does the printer operate normally? Problem solved Go to step 3 3 • Replacing the relevant unit: • Replace the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved
  • Code: 2000
  • Description: Software error
  • Remedy: 1 • Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2 2 • Initializing the MCU PWB: • By using the DIAG command, execute “Slave Initialize”. Turn the power off once and on again. Does the printer operate normally? Problem solved Go to step 3 3 • Replacing the relevant unit: • Replace the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us