Remedy: 1 • Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2 2 • Initializing the MCU PWB: • By using the DIAG command, execute “Slave Initialize”. Turn the power off once and on again. Does the printer operate normally? Problem solved Go to step 3 3 • Replacing the relevant unit: • Replace the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved
Code: 1500
Description: CCNV hardware error
Remedy: 1 • Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2 2 • Replacing the IC concerned: • Replace IC603 for AcuLaser C8600 or IC600 for AcuLaser C7000 (VIPS: E05B93BA) • Replace IC602 for AcuLaser C8600 or IC601 for AcuLaser C7000 In cases other than above, replace the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved
Remedy: 1 • Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2 2 • Checking the SD-RAM: • Remove all SD-RAMs from the RAM slots and then reinsert them in the RAM slots. Be sure to insert the SD-RAMs one by one (S0 and S1) in order so that the SD-RAM error can be identified. Every time you insert an SD-RAM, follow the procedures below and repeat it for each one. 1 Turn the power off. 2 Add the SD-RAM. 3 Turn the power on. • Insert the SD-RAM in the socket until it is locked securely. NOTE: Since the SD-RAM has the right direction to insert, be sure to insert it in the correct direction. Replace or reinstall the relevant part. Go to step 3 3 • Replacing the IC concerned: • Replace IC603 for AcuLaser C8600 or IC600 for AcuLaser C7000 (VIPS: E05B93BA) • Replace IC602 for AcuLaser C8600 or IC601 for AcuLaser C7000 In cases other than above, replace the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved
Code: 1600
Description: Video related hardware error (including PWM IC calibration error)
Remedy: 1 • Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2 2 • Replacing the IC concerned: • Replace IC603 for AcuLaser C8600 or IC600 for AcuLaser C7000 (VIPS: E05B93BA) • Replace IC602 for AcuLaser C8600 or IC601 for AcuLaser C7000 In cases other than above, replace the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved
Code: 1999
Description: Other hardware error
Remedy: 1 • Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2 2 • Initializing the MCU PWB: • By using the DIAG command, execute “Slave Initialize”. Turn the power off once and on again. Does the printer operate normally? Problem solved Go to step 3 3 • Replacing the relevant unit: • Replace the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved
Code: 2000
Description: Software error
Remedy: 1 • Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2 2 • Initializing the MCU PWB: • By using the DIAG command, execute “Slave Initialize”. Turn the power off once and on again. Does the printer operate normally? Problem solved Go to step 3 3 • Replacing the relevant unit: • Replace the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved