PrintCopy.info service

Epson AcuLaser C7000

Error Codes List page 9

  • Code: 624
  • Description: IBT service life
  • Remedy: 1 • Initial checking: Is there any parts of wrong specifications used, improper mounting, damage, distortion, dirt, or adherence of foreign matter? • Major parts to be checked: MCU PWB Replace or reinstall the relevant part. Go to step 2 2 • Error Reset and checking: Does the problem still occur after “error reset”? Go to step 3 Problem solved 3 Does the problem occur even after replacing the part(s) concerned? Go to step 4 Problem solved 4 Does the problem occur when the power is turned ON? Go to step 7 Go to step 5 5 Does the problem still occur when the power is turned On again? Go to step 7 Go to step 6 6 Does the problem occur when the power is turned ON and OFF repeatedly? Go to step 7 Go to FIP-2.33 “Noise” 7 • Replacing the MCU and Performing Checks: Does the problem still occur after replacing with the normal MCU? Check the Printer Controller. Problem solved
  • Code: 626
  • Description: 2nd BTR service life
  • Remedy: 1 • Initial checking: Is there any parts of wrong specifications used, improper mounting, damage, distortion, dirt, or adherence of foreign matter? • Major parts to be checked: MCU PWB Replace or reinstall the relevant part. Go to step 2 2 • Error Reset and checking: Does the problem still occur after “error reset”? Go to step 3 Problem solved 3 Does the problem occur even after replacing the part(s) concerned? Go to step 4 Problem solved 4 Does the problem occur when the power is turned ON? Go to step 7 Go to step 5 5 Does the problem still occur when the power is turned On again? Go to step 7 Go to step 6 6 Does the problem occur when the power is turned ON and OFF repeatedly? Go to step 7 Go to FIP-2.33 “Noise” 7 • Replacing the MCU and Performing Checks: Does the problem still occur after replacing with the normal MCU? Check the Printer Controller. Problem solved
  • Code: 627
  • Description: IBT cleaner service life
  • Remedy: 1 • Initial checking: Is there any parts of wrong specifications used, improper mounting, damage, distortion, dirt, or adherence of foreign matter? • Major parts to be checked: MCU PWB Replace or reinstall the relevant part. Go to step 2 2 • Error Reset and checking: Does the problem still occur after “error reset”? Go to step 3 Problem solved 3 Does the problem occur even after replacing the part(s) concerned? Go to step 4 Problem solved 4 Does the problem occur when the power is turned ON? Go to step 7 Go to step 5 5 Does the problem still occur when the power is turned On again? Go to step 7 Go to step 6 6 Does the problem occur when the power is turned ON and OFF repeatedly? Go to step 7 Go to FIP-2.33 “Noise” 7 • Replacing the MCU and Performing Checks: Does the problem still occur after replacing with the normal MCU? Check the Printer Controller. Problem solved
  • Code: 830
  • Description: Optional double cassette unit LC3 malfunction
  • Remedy:
  • Code: 831
  • Description: Optional single/double cassette unit LC2 malfunction
  • Remedy:
  • Code: 832
  • Description: MP tray malfunction (lift down)
  • Remedy: 1 • Initial checking: Is there any parts of wrong specifications used, improper mounting, damage, distortion, dirt, or adherence of foreign matter? • Major parts to be checked: LIFT MOTOR ASSY, LEVEL SENSOR, MCU PWB P/H HARNESS ASSY, MSI HARNESS ASSY Replace or reinstall the relevant part. Go to step 2 2 • Checking whether the problem lies in engine or controller: Can a test print (single sheet / consecutive printing, about 10 sheets each) be performed normally with the engine alone? Check the Printer Controller. If an error still occurs after replacing, • With the tool: Go to step 3 • Without the tool: Go to step 4] • With the tool: Go to step 3 • Without the tool: Go to step 4 3 • Checking the LIFT MOTOR ASSY: Does the LIFT MOTOR ASSY function properly? . By using the diagnostics commander, check by Digital Output Test device code "2D, 2E". Go to step 6 Go to step 4 4 • Checking for continuity of REGI HARNESS ASSY: Is there normal continuity between J91B . J208? Go to step 5 Replace the REGI HARNESS ASSY. 5 • Checking for continuity of P/H HARNESS ASSY: Is there normal continuity between J20B . J91B? • With the tool: Go to step 6 • Without the tool: Go to step 7 Replace the P/H HARNESS ASSY. 6 • Checking the LEVEL SENSOR: Does the LEVEL SENSOR function properly? . By using the diagnostics commander, check by Digital Input Test device code "2C". Replace the MCU PWB-XL Go to step 7 7 • Checking for continuity of MSI HARNESS ASSY: Is there normal continuity between J201 . J209? Go to step 8 Replace the MSI HARNESS ASSY. 8 • Checking for continuity of P/H HARNESS ASSY: Is there normal continuity between J20A . J91A? Replace the MCU PWB-XL or LIFT MOTOR ASSY LEVEL SENSOR Replace the P/H HARNESS ASSY.