PrintCopy.info service

Epson AcuLaser C4200

Error Codes List page 1

  • Code: 0017 ... 0258
  • Description: 0017 CPU error (undefined interruption) 0081 CPU error (TLB modification exception) 0082 CPU error (TLB miss exception [Load/Fetch]) 0083 CPU error (TLB miss exception [Store]) 0084 CPU error (address error exception [Load/Fetch]) 0085 CPU error (address error exception [Store]) 0086 CPU error (bus error exception [Fetch]) 0087 CPU error (bus error exception [Load/Store]) 0088 CPU error (SYSCALL exception) 0089 CPU error (Break exception) 0090 CPU error (reserving command exception) 0091 CPU error (unused coprocessor exception) 0092 CPU error (FPU exception) 0093 CPU error (TLB exception) 0094 CPU error (XTLB exception) 0095 CPU error (cache exception) 0096 CPU error (Trap exception) 0097 CPU error (FPU exception) 0098 CPU error (watch exception) 0128 ~ 0254 CPU error (undefined trap) 0255 CPU error (NMI exception) 0256 CPU error (divide by 0) 0257 CPU error (arithmetic overflow) 0258 CPU error (break occurrence)
  • Remedy: When a controller related error occurs, make sure to check the initial check items listed below first. If the error still occurs after that, replace the part given on an error basis in the Failed Parts List on the next page to perform troubleshooting. • Initial Check • Check that the printer is grounded properly. • Check that the connectors are connected to the controller board securely and correctly. • Check that the DIMM is connected to the controller board securely and correctly. • Power the printer off and on several times. • Check that the printer is not in electrically noisy environments.
    When powering the printer off and on again, do not turn it on immediately after turning it off. Make sure to wait at least for a few seconds before the power-on.
  • Code: 0800 ... 1021
  • Description: 0800 IPL error (controller defect) 0998 Engine communication error (only when power-on) 0999 Engine flash ROM has no program data 1002 Standard RAM error (standard size is undefined, etc.) 1010 Verification error 1020 RAM error (slot 0) 1021 RAM error (slot 1)
  • Remedy: When a controller related error occurs, make sure to check the initial check items listed below first. If the error still occurs after that, replace the part given on an error basis in the Failed Parts List on the next page to perform troubleshooting. • Initial Check • Check that the printer is grounded properly. • Check that the connectors are connected to the controller board securely and correctly. • Check that the DIMM is connected to the controller board securely and correctly. • Power the printer off and on several times. • Check that the printer is not in electrically noisy environments.
    When powering the printer off and on again, do not turn it on immediately after turning it off. Make sure to wait at least for a few seconds before the power-on.
  • Code: 100
  • Description: - Laser power has weakened.
    - SOS signal cannot be detected
  • Remedy: 1 Connection Check of the HARNESS ASSY ROS Disconnect and reconnect the HARNESS ASSY ROS connector. Does the error recur even when the power is turned off and back on again? Go to Step [2]. End of procedure 2 Continuity Check of the HARNESS ASSY ROS 1. Disconnect P/J151 connector of the ROS ASSY, and P/J15 connector on the PWBA MCU IDTN. 2. Check the continuity of J15<=>J151. Is there normal continuity between them? Go to Step [3]. Replace the HARNESS ASSY ROS. 3 Check of the ROS ASSY Replace the ROS ASSY. Does the error still occur after the replacement? Replace the PWBA MCU IDTN. End of procedure
  • Code: 101
  • Description: - The printer detected that the Temp Sensor is broken.
    - Abnormal high temperature was detected (approx. 250 degrees C or more).
    - Abnormal low temperature was detected during printing (approx. 100 degrees or lower).
    - Abnormal temperature difference was detected between the center and the end of the Fuser Roll.
    - The printer detected that the circuit for the Fuser Roll center sensor is in failure.
    - The printer detected that the Fuser Roll center sensor is abnormal.
    - Abnormal warm-up time was detected. (Ready waiting time exceeded 60 seconds.)
    - Abnormal low temperature was detected (approx. 180 seconds or more).
    - Abnormal Temp sensor warm-up time was detected (approx. 30 minutes or more at 0 degree C or less).
  • Remedy: 1 Initial Check Are the parts listed below installed incorrectly? Fuser unit Do not turn the printer On and Off with the Fuser unit removed. Otherwise you may get an electric shock. Reinstall the part(s) correctly. Go to Step [2]. 2 Check of the Fuser unit connector Disconnect the Fuser unit. Are the connector pins bent or broken? Go to Step [3]. Replace the defective part. 3 Check of the Fuser unit Replace the Fuser unit with a new one. Does the error still occur after the replacement? Go to Step [4]. End of procedure 4 Check of the LVPS Replace the LVPS with a new one. Does the error still occur after the replacement? Replace the PWBA MCU IDTN. End of procedure
  • Code: 102
  • Description: NV-RAM error
  • Remedy: 1 Does the error recur even when the power is turned off and back on again? Go to Step [2]. End of procedure 2 Remove the part below, and reinstall it securely. • PWBA MCU IDTN Does the error recur even when the power is turned off and back on again? Replace the PWBA MCU IDTN. End of procedure
  • Code: 103
  • Description: The HOLDER ASSY CTD power has weakened.
  • Remedy: 1 Initial Check Are the parts listed below installed incorrectly? HOLDER ASSY CTD Reinstall the part(s) correctly. Go to Step [2]. 2 Continuity Check of the HARNESS ASSY FSR/ADC 1. Disconnect P/J136 connector on the HOLDER ASSY CTD, and P/J36 connector on the PWBA MCU IDTN. 2. Check the continuity of J136<=>J36. Is there normal continuity between them? Go to Step [3]. Replace the HARNESS ASSY FSR/ADC. 3 Check of the HOLDER ASSY CTD Replace the HOLDER ASSY CTD with a new one. Does the error still occur after the replacement? Replace the PWBA MCU IDTN. End of procedure