  • Code: 1500
  • Description: CCNV hardware error
  • Remedy: 1 Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2. 2 Replacing the IC concerned: • Replace IC601 (VIP2: E05B93BA). • Replace IC600 (PWM). In cases other than above, replace the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved.
  • Code: 1550
  • Description: Compression SRAM initialization hardware error
  • Remedy: 1 Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2. 2 Checking the SD-RAM: • Remove all SD-RAMs from the RAM slots and then reinsert them in the RAM slots. Be sure to insert the SD-RAMs one by one (S0 and S1) in order so that the SD-RAM error can be identified. Every time you insert an SD-RAM, follow the procedures below and repeat it for each one. 1. Turn the power off. 2. Add the SD-RAM. 3. Turn the power on. • Insert the SD-RAM in the socket until it is locked securely. NOTE: Since the SD-RAM has the right direction to insert, be sure to insert it in the correct direction. Replace or reinstall the relevant part. Go to step 3. 3 Replacing the IC concerned: • Replace IC601 (VIP2: E05B93BA). • Replace IC600 (PWM). In cases other than above, replace the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved.
  • Code: 1600
  • Description: Video related hardware error (including PWM IC calibration error)
  • Remedy: 1 Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2 2 Replacing the IC concerned: • Replace IC601 (VIP2: E05B93BA). • Replace IC600 (PWM). In cases other than above, replace the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved.
  • Code: 1700
  • Description: Built-in network hardware error
  • Remedy: 1 Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2. 2 Checking the network setting • Check if the existing network is operating normally. • Print the network status sheet to check if the every setting is correct. • Check if the network environment of the client side is correct. Problem solved. Go to step 3. 3 Replacing the relevant unit: Replacing the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved.
  • Code: 1800
  • Description: DIMM SPD error
  • Remedy: 1 Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. Go to step 2. 2 Replacing CODE ROM (C309PROG): • Replace the mounted CODE ROM with another one for checking. Replace the CONTROLLER PWB. Problem solved.
  • Code: 1999
  • Description: Other hardware error
  • Remedy: 1 Initial setting: • Remove all the optional units and modules related to the electrical system and bring the printer back to the standard status. • Check if all connectors are properly connected to the CONTROLLER PWB. Replace or reinstall the relevant part. • With the tool: Go to step 2. • Without the tool: Go to step3. 2 Initializing the MCU PWB: • By using the DIAG command, execute “Slave Initialize”. Turn the power off once and on again. Does the printer operate normally? Problem solved. Go to step 3. 3 Replacing the relevant unit: • Replace the CONTROLLER PWB. Replace or reinstall the relevant part. Problem solved.