Causes: Scanner area error (Scanner Motor rotation error)
Remedy: 1. Check the harness/connector connection between the DC Controller PCB and the Laser Scanner Unit. 2. Check the harness/connector connection between the Relay PCB and the Laser Scanner Unit. 3. Replace the Laser Scanner Unit.
Code: E196-0000
Description: DC Controller error
Causes: Update of the DC Controller failed. (RFU mode right after the startup)
Remedy: 1. Replace the DC Controller PCB.
Code: E196-1000
Description: ROM writing/reading error (Main ROM)
Causes: Error in writing/reading of main program in the Main Controller PCB (Main ROM).
Remedy: 1. Update the firmware. 2. Replace the Main Controller PCB.
Code: E196-2000
Description: ROM writing/reading error (ROM for storing setting values)
Causes: Error in writing/reading of the setting values storage area in the Main Controller PCB (ROM for storing setting values).
Remedy: 1. Update the firmware. 2. Replace the Main Controller PCB.
Code: E196-3000
Description: ROM writing/reading error (eMMC)
Causes: Unable to read/write data from the eMMC. The eMMC failure occurred.
Remedy: 1. Update the firmware. 2. Replace the Main Controller PCB.
Code: E196-3001
Description: ROM-ID mismatch (eMMC)
Causes: The eMMC has been replaced wrongly. The eMMC failure occurred.
Remedy: 1. Update the firmware. 2. Replace the Main Controller PCB.