Description: Thermistor is not connected
During walm-up rotation, the thermistor connection signal (FUSER CNCTX) is open.
Remedy: - Confirm the cable connection - Replace the cable exchange, and established - Replace the fixing unit - Replace the DC controller PCB.
Code: E009-0001
Description: Error in pressure/release of fixing film unit
In case that the output of fixing automatic pressure phase sensor is not changed although rotating/reversing the fixing motor
Remedy: Check the pressure/release mechanism. Check the connection of the connector. Replace the motor.
Code: E012-0000
Description: Drum/ITB motor error
Lock of the motor fails to be detected 3 sec or more after the motor starts to operate.
Remedy: Check on connection of the connector, Replace the motor
Code: E013-0001
Description: Error in the waste toner motor
Detects the fault in the waste toner motor
Remedy: Replace the waste toner motor.
Code: E013-0002
Description: Error in the waste toner motor
Indicates that the waste toner motor does not rotate due to the open circuit.
Remedy: Replace the waste toner motor. Replace the DC controller PCB.
Code: E015-0000
Description: Error in the registration/multifeeder motor
Indicates that the signal indicates the motor rotates with the target speed is not sent to the port after passing more than 3 sec from the startup of the motor.
Remedy: Check on connection of the connector, Replace the motor