Description: The fixing unit has overheated. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR).
The power has been turned off and then on without resetting the error.
Remedy: Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
Code: E002-0000
Description: The fixing unit has overheated. After correcting the error, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The reading of the main thermistor has exceeded 70 deg C, but does not reach 100 deg C within 2.5 sec thereafter.
Remedy: Disconnect and then connect J508 of the DC controller PCB. Disconnect and then connect the connectors of the fixing unit. Check the wiring between the main/sub thermistor and the DC controller. Check the mounting/soiling of the main thermistor. Replace the fixing heater. Replace the AC driver PCB. Replace the DC controller PCB.
Code: E002-0001
Description: The fixing unit has overheated. After correcting the error, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The reading of the main thermistor has exceeded 100 deg C, but does not reach 150 deg C within 2.5 min thereafter)
Remedy: Disconnect and then connect J508 of the DC controller PCB. Disconnect and then connect the connectors of the fixing unit. Check the wiring between the main/sub thermistor and the DC controller. Check the mounting/soiling of the main thermistor. Replace the fixing heater. Replace the AC driver PCB. Replace the DC controller PCB.
Code: E002-0010
Description: The fixing unit has overheated. After correcting the error, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The power has been turned on without resetting the error.
Remedy: Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
Code: E003-0000
Description: The fixing unit temperature is abnormally low. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The reading of the main thermistor has exceeded 100 deg C, but is 70 deg C or less for 2 sec thereafter.
Remedy: Disconnect and then connect J508 of the DC controller PCB. Disconnect and then connect the connectors of the fixing unit. Check the wiring between the main/sub thermistor and the DC controller PCB. Check the mounting/soiling of the main thermistor. Replace the fixing heater. Replace the AC driver PCB. Replace the DC controller PCB.
Code: E004-0000
Description: The fixing unit has a fault. (protective circuit ON) After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
While the sub heater is on, the SSR for the heater drive has a short-circuit for 5 sec or more.
Remedy: Replace the AC driver PCB. Replace the DC controller PCB.