Description: Failure in main/sub thermistor
When disconnection is detected with connector of the main/sub thermistor for 30 sec continuously while DC controller is working.
Remedy: Clear the error in Service Mode: COPIER > FUNCTION > CLEAR > ERR. Replace the main thermistor (film unit). Replace DC controller PCB.
Code: E007-0000
Description: The rotation of the fixing film is faulty.
While the fixing motor is rotating, the marker signal is not detected for 6 sec with the reading of the main thermistor indicating 100 deg C or more.
Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR. Replace the main thermistor. Replace the DC controller PCB.
Code: E010-0001
Description: The rotation of the main motor is faulty.
Detection is executed every 100 msec after the start of motor rotation; however, the drive detection signal is absent for 2 sec.
Remedy: Replace the main motor. Replace the DC controller PCB.
Code: E010-0002
Description: The rotation of the main motor is faulty.
During motor rotation, detection is executed every 100 msec; however, the drive signal is absent 5 times in sequence.
Remedy: Replace the main motor. Replace the DC controller PCB.
Code: E014-0001
Description: The rotation of the fixing motor is faulty.
Detection is executed every 100 msec after the start of motor rotation; however, the drive detection signal is absent for 2 sec.
Remedy: Replace the fixing motor. Replace the DC controller PCB.
Code: E014-0002
Description: The rotation of the fixing motor is faulty.
During motor rotation, detection is executed every 100 msec; however, the drive signal is absent 5 times in sequence.
Remedy: Replace the fixing motor. Replace the DC controller PCB.