Description: Thermistor disconnection detection error
When disconnection is detected with connector (J214) for 30 sec continuously.
Remedy: 1.Check connection of the Connector (J214). 2.Replace the Film Unit. 3.Replace the Fixing Assembly. 4.Replace the DC Controller PCB (PCB4).
Code: E010-0001
Description: Unstable rotation of the Main Motor (M1)
Detection is executed every 100 msec after the start of motor rotation; however, the drive detection signal is absent for 2 sec.
Remedy: 1.Replace the Main Motor (M1). 2.Replace the DC Controller PCB (PCB4).
Code: E010-0002
Description: Unstable rotation of the Main Motor (M1)
During motor rotation, detection is executed every 100 msec; however, the drive signal is absent 5 times in sequence.
Remedy: 1.Replace the Main Motor (M1). 2.Replace the DC Controller PCB (PCB4).
Code: E014-0001
Description: Unstable rotation of the Fixing Motor (M2)
Detection is executed every 100 msec after the start of motor rotation; however, the drive detection signal is absent for 2 sec.
Remedy: 1.Replace the Fixing Motor (M2). 2.Replace the DC Controller PCB (PCB4).
Code: E014-0002
Description: Unstable rotation of the Fixing Motor (M2)
During motor rotation, detection is executed every 100 msec; however, the drive signal is absent 5 times in sequence.
Remedy: 1.Replace the Fixing Motor (M2). 2.Replace the DC Controller PCB (PCB4).
Code: E019-0000
Description: Error in Waste Toner Sensor (S17)
Warning when the sensor goes on for 2000 consecutive sheets, and error when the sensor goes on for 100 consecutive sheets.
* Error occurs after the delivery if a paper in passage exists.
Remedy: 1.Replace the Waste Toner Sensor (S17). 2.Replace the DC Controller PCB (PCB4).