Description: Fixing sub thermistor 1(THM1-2)abnormal temperature rise (circuit abnormality). Fixing sub thermistor 1(THM1-2) detected abnormal high temperature. (software detection)
Remedy: 1. Check the detection temperature of the fixing sub thermistor 1 in service mode. A. In case that the detection temperature is 250 degC A-1. The cable of the fixing sub thermistor 1 (THM-2) is caught -> replace the fixing belt unit B. In case that the detection temperature is other than 250 degC B-1. Location of the fixing main thermistor is inappropriate -> replace the fixing belt unit B-2. Replace the DC controller PCB
Code: E001-0013
Description: Fixing sub thermistor 2(THM1-3)abnormal temperature rise (circuit abnormality). Fixing sub thermistor 2(THM1-3) detected abnormal high temperature. (software detection)
Remedy: 1. Check the detection temperature of the fixing sub thermistor 2 in service mode. A. In case that the detection temperature is 250 degC A-1. The cable of the fixing sub thermistor 2 (THM-3) is caught -> replace the fixing belt unit B. In case that the detection temperature is other than 250 degC B-1. Location of the fixing main thermistor is inappropriate -> replace the fixing belt unit B-2. Replace the DC controller PCB
Code: E001-0102
Description: Abnormal temperature rise of pressure subthermistor 1 (THM3) (circuit failure). Pressure subthermistor 1 (THM3) sensed an abnormal high temperature. (ASIC detection)
Remedy: 1. Check the detection temperature of the pressure sub thermistor 1 in service mode. A. In case that the detection temperature is 250 degC A-1. The cable of the pressure sub thermistor 1 (THM-3) is caught -> replace the pressure stay B. In case that the detection temperature is other than 250 degC B-1. The pressure main thermistor is disconnected, the harness is disconnected, foreign substance is gotten in, or failure -> replace the main thermistor or pressure stay B-2. Replace the DC controller PCB
Code: E001-0103
Description: Abnormal temperature rise of pressure subthermistor 2 (THM4) (circuit failure). Pressure subthermistor 2 (THM4) sensed an abnormal high temperature. (ASIC detection)
Remedy: 1. Check the detection temperature of the pressure sub thermistor 2 in service mode. A. In case that the detection temperature is 250 degC A-1. The cable of the pressure sub thermistor 2 (THM-4) is caught -> replace the pressure stay B. In case that the detection temperature is other than 250 degC B-1. The pressure main thermistor is disconnected, the harness is disconnected, foreign substance is gotten in, or failure -> replace the main thermistor or pressure stay B-2. Replace the DC controller PCB
Code: E001-0111
Description: Pressure main thermistor abnormal temperature rise (circuit abnormality). Pressure main thermistor (THM2) detected abnormal high temperature. (software detection)
Remedy: 1. Check the detection temperature of the pressure main thermistor in service mode. A. In case that the detection temperature is 250 degC A-1. The cable of the pressure main thermistor (THM-2) is caught -> replace the thermistor or the pressure stay B. In case that the detection temperature is other than 250 degC B-1. Replace the DC controller PCB
Code: E001-0112
Description: Pressure sub thermistor 1(THM3)abnormal temperature rise (circuit abnormality). Pressure sub thermistor 1(THM3) detected abnormal high temperature. (software detection)
Remedy: 1. Check the detection temperature of the pressure sub thermistor 1 in service mode. A. In case that the detection temperature is 250 degC A-1. The cable of the pressure sub thermistor 1 (THM-3) is caught -> replace the pressure stay B. In case that the detection temperature is other than 250 degC B-1. The pressure main thermistor is disconnected, the harness is disconnected, foreign substance is gotten in, or failure -> replace the main thermistor or pressure stay B-2. Replace the DC controller PCB