PrintCopy.info service

Canon iR Advance C2230i

Error Codes List page 2

  • Code: E001-0007
  • Description: Edge Thermistor high temperature detection
    Sub Thermistor 2 hardware error detection signal is continued for 1 sec or longer.
  • Remedy: Fixing Assembly error, Fixing temperature detection error 1. Check failure between the DC Controller PCB (UN09/ J12) and the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable, open circuit, connector disconnection). -> Replace the part in the case of trapped cable/open circuit 2. Disconnect the connector of DC Controller PCB (UN09/ J12) and start the host machine to check the reading value of the following: service mode > COPIER > DISPLAY > ANALOG > FIX-C Check the reading value of the following: service mode > COPIER > DISPLAY > ANALOG > FIX-E3 => When the value is 40 deg C or higher 3-1. Replace the DC Controller PCB (UN09) => When the value is lower than 40 deg C 3-2. Replace the Fixing Assembly NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
  • Code: E001-0008
  • Description: Displacement detection
    The temperature difference between the Sub Thermistor 1 (TH3) and the Sub Thermistor 2 (TH4) remained 45 deg C or more for 1 second or more.
  • Remedy: Fixing Assembly error, Fixing temperature detection error 1. Check failure between the DC Controller PCB (UN09/ J12) and the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable, open circuit, connector disconnection). -> Replace the part in the case of trapped cable/open circuit 2. Disconnect the connector of DC Controller PCB (UN09/ J12) and start the host machine to check the reading value of the following: service mode > COPIER > DISPLAY > ANALOG > FIX-E2,FIX-E3 => When the value of either one is 40 deg C or higher 3-1. Replace the DC Controller PCB (UN09) => When the both values are lower than 40 deg C 3-2. Replace the Fixing Assembly NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
  • Code: E002-0006
  • Description: Detection of abnormal temperature increase
    Fixing Assembly error, Fixing temperature detection error
  • Remedy: 1. Check the location for voltage of the Fixing Assembly -> Replace with a correct Fixing Assembly for the location in the case of mismatching. 2. Check the location for voltage of the AC Driver PCB (UN14) -> Replace with a correct AC Driver PCB (UN14) for the location in the case of mismatching. 3. Check failure between the AC Driver PCB (UN14/J103) and the Fixing Assembly (UN37/J123, UN13/J13). (trapped cable, open circuit, connector disconnection) -> Replace the part in the case of trapped cable/open circuit 4. Replace the AC Driver PCB (UN14) 5. Replace the Fixing Assembly 6. Replace the DC Controller PCB (UN09) NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
  • Code: E003-0001
  • Description: Thermistor open circuit detection
    In the period from initial rotation to printing, Main Thermistor 1 detected a temperature of 22 deg C or lower for more than 5 seconds.
  • Remedy: Fixing Assembly error, Fixing temperature detection error 1. Check failure between the DC Controller PCB (UN09/ J12) and the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable, open circuit, connector disconnection). -> Replace the part in the case of trapped cable/open circuit 2. Replace the Fixing Assembly 3. Replace the DC Controller PCB (UN09) NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
  • Code: E003-0002
  • Description: Thermistor open circuit detection
    In the period from initial rotation to printing, Main Thermistor 2 detected a temperature of 40 deg C or lower for more than 3 seconds.
  • Remedy: Fixing Assembly error, Fixing temperature detection error 1. Check failure between the DC Controller PCB (UN09/ J12) and the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable, open circuit, connector disconnection). -> Replace the part in the case of trapped cable/open circuit 2. Replace the Fixing Assembly 3. Replace the DC Controller PCB (UN09) NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
  • Code: E003-0003
  • Description: Thermistor open circuit detection
    In the period from initial rotation to printing, Sub Thermistor 1 detected a temperature of 40 deg C or lower for more than 3 seconds.
  • Remedy: Fixing Assembly error, Fixing temperature detection error 1. Check failure between the DC Controller PCB (UN09/ J12) and the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable, open circuit, connector disconnection). -> Replace the part in the case of trapped cable/open circuit 2. Replace the Fixing Assembly 3. Replace the DC Controller PCB (UN09) NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us