PrintCopy.info service

Canon iR Advance 715iFZ

Error Codes List page 50

  • Code: E840-0001-05
  • Description: Pressure Release Mechanism error
  • Causes: An error was detected at the pressure/separation operation.
  • Remedy: [Related parts] - Fixing Assembly - DC Controller PCB [Remedy] Check/replace the related harness/cable, connector and parts.
  • Code: E880-0001-00
  • Description: Controller Fan error
  • Causes: It was detected that the Controller Fan was locked.
  • Remedy: [Related parts] R1.00 - Cable between the Main Controller PCB (UN25/J15) and the Controller Fan (FM12) - Controller Fan (FM12) - Main Controller PCB (UN25) [Remedy] Perform the following in the order while checking whether the error is cleared. - Check the connectors of the Controller Fan. - Visually check rotation of the Controller Fan. a. If it is not rotated, replace the Controller Fan. b. If it is rotated, replace the Main Controller PCB.
  • Code: E880-0003-00
  • Description: Controller Fan error
  • Causes: It was detected that the Controller Fan was locked.
  • Remedy: [Related parts] R1.00 - Cable between the Main Controller PCB and the Controller Fan - Controller Fan - Main Controller PCB [Remedy] Perform the following in the order while checking whether the error is cleared. - Check the connectors of the Controller Fan. - Visually check rotation of the Controller Fan. a. If it is not rotated, replace the Controller Fan. b. If it is rotated, replace the Main Controller PCB.
  • Code: E880-0005-00
  • Description: Error in Controller Fan
  • Causes: Fan lock of the HDD Cooling Fan was detected
  • Remedy: Check if the connector is connected. It the connection is OK, replace the HDD Cooling Fan.
  • Code: E881-0001-00
  • Description: Board over heat error
  • Causes: Abnormal temperature of the Main Controller CPU was detected.
  • Remedy: [Remedy] Perform the following in the order while checking whether the error is cleared. a. If the error occurred during a service visit and then occurred again, replace the Main Controller PCB. b. If the error does not occur during a service visit but is found in the log: 1. Clean the inlet on the side where the fan is installed and remove dust. 2. Remove dust from the Controller fan. 3. If the space on the side where the fan is installed is less than 10 cm, ask the customer to secure enough space.
  • Code: E996-0001-05
  • Description: Error for collecting sequence jam log (Printer)
  • Causes: Error for collecting jam log (Printer)
  • Remedy: [Remedy] Collect debug log and contact to the sales company. [Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> JM-ERR-R" to "1", it is handled as an error instead of a jam from the first occurrence.