Causes: Movement: HDD failure is expected to occur in a short time due to occurrence of physical error in HDD. It does not occur in the HDD of mirroring configuration. Cause: Error in the S.M.A.R.T. value of HDD
Remedy: 1. Back up the data stored in HDD. 2. Replace the HDD. 3. Restore the data. S.M.A.R.T. (Self-Monitoring Analysis and Reporting Technology): Self-diagnosis function built in the HDD. The occurrence rate of reading error, reading and writing speed, the total number of Motor start-up and stop times, the total length of power-on time, etc. are monitored.
Code: 31-0009
Description: FLASH failure prediction alarm
Causes: Error in the S.M.A.R.T. value of FLASH memory It indicates a physical error of the FLASH memory, which is expected to soon lead to a failure.
Remedy: S.M.A.R.T. (Self-Monitoring Analysis and Reporting Technology) = It is a self-diagnosis function built in the FLASH memory, and monitors the occurrence rate of reading errors, reading/writing speed, total number of times of motor start-up/stop, total length of power-on time, etc. Continuously using the machine without taking any measures may lead to E614. Measures: Back up the data stored in the FLASH memory, and restore the data after replacing the FLASH memory.
Code: 31-0060
Description: Warning in accessing the NVRAM
Causes: Communication with EEPROM in the DCON PCB was not available.
Remedy: Replace the DCON PCB.
Code: 31-0061
Description: Warning in accessing the NVRAM
Causes: Communication with EEPROM in the DCON PCB was not available.
Remedy: Replace the DCON PCB.
Code: 34-0050
Description: Laser Scanner EEPROM checksum alarm
Causes: An error in data in the EEPROM installed in the Laser Scanner PCB was detected. Detection condition/timing: When the DCON is started, data in the EEPROM of the Laser Scanner is retrieved.
Remedy: [Related parts] - Laser Driver PCB - Harness between the DC Controller PCB and the Laser Driver PCB Remedy: [Remedy] Check/replace the related parts.
Code: 40-0013
Description: Tranfer Roller life value reaching alarm
Causes:
Remedy: The life value of a target part reached the number of days left as set in COPIER > OPTION > PMDLV- D > TR-ROLL.