PrintCopy.info service

Canon iR Advance 6275i

Error Codes List page 1

  • Code: E000-0001
  • Description: Fixing Assembly low temperature error
    Temperature of the Fixing Main Thermistor (THM1) does not reach 70 degC although 20 seconds have passed after starting the Fixing Roller temperature control.
  • Remedy: 1. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit) -> Replace the Heater Assembly. 2. Check the connection between the Main Driver PCB (PCB2) and the Fixing Power Supply PCB (PCB10) (connector disconnection, open circuit, the caught cable). 3. Replace the Fixing Power Supply PCB (PCB10). 4. Replace the Main Driver PCB (PCB2). 5. Replace the DC Controller PCB (PCB1).
  • Code: E000-0002
  • Description: Fixing Assembly low temperature error
    Temperature of the Fixing Main Thermistor (THM1) does not reach 10 degC although 20 seconds have passed after starting the Fixing Roller temperature control.
  • Remedy: 1. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit) -> Replace the Heater Assembly. 2. Check the connection between the Main Driver PCB (PCB2) and the Fixing Power Supply PCB (PCB10) (connector disconnection, open circuit, the caught cable). 3. Replace the Fixing Power Supply PCB (PCB10). 4. Replace the Main Driver PCB (PCB2). 5. Replace the DC Controller PCB (PCB1).
  • Code: E000-0010
  • Description: Fixing Assembly low temperature error
    Turning OFF and then ON the power without clearing the error.
  • Remedy: Clear the error.
  • Code: E001-0002
  • Description: Fixing Assembly high temperature error (software detection)
    • The Fixing Main Thermistor (THM1) detects 230 degC or higher. • The Fixing Sub Thermistor 1 (THM2)/Fixing Sub Thermistor 2 (THM3) detects 230 degC or higher for 2 consecutive seconds.
  • Remedy: 1. Check if the cable of the Thermistor is caught. -> Replace the Thermistors. -> Replace the Fixing Upper Unit. 2. IH control error. -> Replace the Fixing Power Supply PCB (PCB10), the DC Controller PCB (PCB1), or the Main Driver PCB (PCB2).
  • Code: E001-0003
  • Description: Fixing Assembly high temperature error (hardware detection)
    • The Fixing Main Thermistor (THM1) detects hardware overheating. • The Fixing Sub Thermistor 1 (THM2)/Fixing Sub Thermistor 2 (THM3) detects hardware overheating.
  • Remedy: 1. Check if the cable of the Thermistor is caught. -> Replace the Thermistors. -> Replace the Fixing Upper Unit. 2. Replace the Main Driver PCB (PCB2). 3. Replace the DC Controller PCB (PCB1).
  • Code: E001-0004
  • Description: Fixing Assembly high temperature error (hardware detection)
    Abnormal temperature difference among the Thermistors was detected.
  • Remedy: 1. Check if the cable of the Thermistor is caught or is open circuit. -> Replace the Thermistors. -> Replace the Fixing Upper Unit. 2. Replace the Main Driver PCB (PCB2). 3. Replace the DC Controller PCB (PCB1). 4. Check if the Fixing Shutter operates. -> Replace the Fixing Assembly.