Description: Fixing Assembly high temperature error
Turning OFF and then ON the power without clearing the error.
Remedy: Clear the error.
Code: E002-0001
Description: Fixing Assembly temperature rise error
• Temperature of the Fixing Main Thermistor (THM1) does not reach 100 degC although 12 seconds have passed since it reached above 70 degC after starting the Fixing Roller temperature control. • Temperature of the Fixing Main Thermistor does not reach 130 degC although 12 seconds have passed since it reached above 100 degC after starting the Fixing Roller temperature control. • Temperature of the Fixing Main Thermistor does not reach 150 degC although 20 seconds have passed since it reached above 130 degC after starting the Fixing Roller temperature conrtol.
Remedy: 1. Check the connection of the Fixing Main Thermistor (THM1). -> Replace the Fixing Main Thermistor Unit. 2. Check the installation of the Fixing Main Thermistor. -> Replace the Fixing Upper Unit. 3. Replace the Fixing Power Supply PCB (PCB10). 4. Replace the Main Driver PCB (PCB2). 5. Replace the DC Controller PCB (PCB1). 6. Replace the Relay PCB (PCB5).
Code: E002-0010
Description: Fixing Assembly temperature rise error
Turning OFF and then ON the power without clearing the error.
Remedy: Clear the error.
Code: E003-0000
Description: Fixing Assembly temperature decrease error
The Fixing Main Thermistor (THM1) detects 70 degC or lower for 2 seconds or longer although the temperature reached above 100 degC after starting the Fixing Roller temperature control.
Remedy: 1. Check the connection of the Fixing Main Thermistor (THM1). -> Replace the Fixing Main Thermistor Unit. 2. Check the installation of the Fixing Main Thermistor. -> Replace the Fixing Upper Unit. 3. Replace the Fixing Power Supply PCB (PCB10). 4. Replace the Main Driver PCB (PCB2). 5. Replace the DC Controller PCB (PCB1). 6. Replace the Relay PCB (PCB5).
Code: E003-0010
Description: Fixing Assembly temperature decrease error
Turning OFF and then ON the power without clearing the error.
Remedy: Clear the error.
Code: E004-0010
Description: Fixing Power Supply error
Turning OFF and then ON the power without clearing the error.