Description: Thermistor disconnection detection error
The disconnection of the thermistor connector was detected for 30msec on end.
Remedy: 1. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit)
2. Check the connection between the AC Driver PCB (PCB4) and Fixing Assembly.
3. Replace the Fixing Assembly.
4. Replace the AC Driver PCB (PCB4).
5. Replace the DC Controller PCB (PCB1).
Code: E010-0001
Description: Main Motor (M2) rotation error
The lock signal was not detected for 2.0 seconds while detecting the signal every 100msec since starting the drive of the motor.
Remedy: 1. Check the connector connection between the Main Motor (M2) and the DC Controller PCB (PCB1).
2. Replace the Main Motor (M2).
3. Replace the DC Controller PCB (PCB1).
Code: E010-0002
Description: Main Motor (M2) rotation error
The lock signal was not detected 5 times in a row for 500msec while detecting the signal every 100msec during driving (after the lock signal detection).
Remedy: 1. Check the connector connection between the Main Motor (M2) and the DC Controller PCB (PCB1).
2. Replace the Main Motor (M2).
3. Replace the DC Controller PCB (PCB1).
Code: E013-0000
Description: Waste Toner Motor (M3) rotation error
The same level of the lock signal was detected 375 times in a row while detecting the signal every 2msec.
* If paper is being fed, the error occurs after the paper has been delivered.
Remedy: 1. Check the connector connection between the Waste Toner Motor (M3) and the DC Controller PCB (PCB1).
2. Replace the Waste Toner Motor (M3).
3. Replace the DC Controller PCB (PCB1).
Code: E014-0001
Description: Fixing Motor (M1) rotation error
The lock signal was not detected for 2.0 seconds while detecting the signal every 100msec since starting the drive of the motor.
Remedy: 1. Check the connector connection between the Fixing Motor (M1) and the DC Controller PCB (PCB1).
2. Replace the Fixing Motor (M1).
3. Replace the DC Controller PCB (PCB1).
Code: E014-0002
Description: Fixing Motor (M1) rotation error
The lock signal was not detected 5 times in a row for 500msec while detecting the signal every 100msec during driving (after the lock signal detection).
Remedy: 1. Check the connector connection between the Fixing Motor (M1) and the DC Controller PCB (PCB1).
2. Replace the Fixing Motor (M1).
3. Replace the DC Controller PCB (PCB1).