PrintCopy.info service

Canon Satera LBP7200CN

Error Codes List page 1

  • Code: E000
  • Description: Failure in fixing assembly start-up.
  • Causes: If increasing temperature is not detected by main thermistor after current distribution to the heater is started. Cause Open circuit in the main thermistor, disconnection in the fixing heater, failure in DC controller PCB
  • Remedy: - Check the connectors of fixing assembly, DC controller PCB, and fixing power supply assembly. - Replace the fixing film unit - Replace the fixing power unit - Replace the DC controller PCB
  • Code: E001-0000
  • Description: Abnormal high temperature in fixing assembly
  • Causes: If abnormal high temperature is detected by main thermistor. Cause Failure in sub thermistor, failure in DC controller PCB.
  • Remedy: - Check the connectors of fixing assembly and DC controller PCB - Replace the fixing film unit - Replace the fixing power unit - Replace the DC controller PCB
  • Code: E001-0001
  • Description: Abnormal high temperature in fixing assembly
  • Causes: If abnormal high temperature is detected by sub thermistor (caused by sub thermistor). Cause Failure in sub thermistor, failure in DC controller PCB
  • Remedy: - Check the connectors of fixing assembly and DC controller PCB - Replace the fixing film unit - Replace the fixing power unit - Replace the DC controller PCB
  • Code: E003-0000
  • Description: Abnormal low temperature in fixing assembly
  • Causes: If decreasing temperature is detected after the main thermistor reaches a specified temperature. Cause Failure in fixing power unit, open circuit in the main thermistor, failure in DC controller PCB.
  • Remedy: - Check the connectors of fixing assembly and DC controller PCB - Replace the fixing film unit - Replace the fixing power unit - Replace the DC controller PCB
  • Code: E003-0001
  • Description: Abnormal low temperature in fixing assembly
  • Causes: If decreasing temperature is detected after the sub thermistor reaches a specified temperature. (cause by sub thermistor) Cause Failure in fixing power unit, open dircuit in the sub thermistor, failure in DC controller PCB.
  • Remedy: - Check the connectors of fixing assembly and DC controller PCB - Replace the fixing film unit - Replace the fixing power unit - Replace the DC controller PCB
  • Code: E004
  • Description: Error in fixing current drive circuit.
  • Causes: Zero cross signal is not detected within specified time. Cause Failure in fixing control circuit assembly.
  • Remedy: - Check the connectors of fixing assembly and DC controller PCB - Replace the fixing power unit