Causes: When 2.5 sec passed after activation of the cyan drum motor, the cycle of the drum motor speed detection signal does not become its specified value. Cause Error in drum motor, error in DC controller PCB.
Remedy: - Replacement of drum motor - Replacement of DC controller PCB
Code: E012-0007
Description: Error in activation of motor
Causes: After the cyan drum motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more. Cause Error in drum motor, error in DC controller PCB.
Remedy: - Replacement of drum motor - Replacement of DC controller PCB
Code: E012-0008
Description: Error in activation of motor
Causes: When 2.5 sec passed after activation of the black drum motor, the cycle of the drum motor speed detection signal does not become its specified value. Cause Error in drum motor, error in DC controller PCB.
Remedy: - Replacement of drum motor - Replacement of DC controller PCB
Code: E012-0009
Description: Error in activation of motor
Causes: After the black drum motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more. Cause Error in drum motor, error in DC controller PCB.
Remedy: - Replacement of drum motor - Replacement of DC controller PCB
Code: E014-0000
Description: Error in activation of fixing motor
Causes: When 2.5 sec passed after activation of fixing motor, the cycle of the fixing motor speed detection signal does not become its specified value. Cause Error in fixing motor, error in DC controller PCB.
Remedy: - Replacement of fixing motor - Replacement of DC controller PCB
Code: E014-0001
Description: Error in activation of fixing motor
Causes: After the fixing motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more. Cause Error in fixing motor, error in DC controller PCB.
Remedy: - Replacement of fixing motor - Replacement of DC controller PCB