  • Code: E000 0000
  • Description: Fixing startup failure
  • Remedy: 1) Reconnect the connector on the Engine Controller PCB. 2) Turn OFF the power supply switch, and remove the Fixing Assembly. Measure the resistance value between the connector (FSRTH) at the Fixing Assembly side and grounding. If the resistance value is not between 368k ohm and 512k ohm (normal temperature), replace the Fixing Assembly. 3) If the connector at the Fixing Assembly side does not have induction while the assembly is removed, replace the assembly. 4) Replace the Engine Controller PCB.
  • Code: E001 0000
  • Description: Abnormal high temperature in fixing (The main thermistor detected a temperature of higher than 255 degree C.)
  • Remedy: 1) Reconnect the connector on the Engine Controller PCB. 2) Turn OFF the power supply switch, and remove the Fixing Assembly. Measure the resistance value between the connector (FSRTH) at the Fixing Assembly side and grounding. If the resistance value is 1k ohm or lower, replace the Fixing Assembly. 3) Replace the Engine Controller PCB.
  • Code: E001 0001
  • Description: Abnormal high temperature in fixing (The sub thermistor detected a temperature of higher than 290 degree C.
  • Remedy: 1) Reconnect the connector on the Engine Controller PCB. 2) Turn OFF the power supply switch, and remove the Fixing Assembly. Measure the resistance value between the connector (FSRTH) at the Fixing Assembly side and grounding. If the resistance value is 1k ohm or lower, replace the Fixing Assembly. 3) Replace the Engine Controller PCB.
  • Code: E003 0000
  • Description: Abnormal low temperature in fixing (The main thermistor detected a temperature of lower than 120 degree C for more than 1 second when 20 seconds elapsed after start of the power distribution to the heater.)
  • Remedy: 1) Reconnect the connector on the Engine Controller PCB. 2) Turn OFF the power supply switch, and remove the Fixing Assembly. Measure the resistance value between the connector (FSRTH) at the Fixing Assembly side and grounding. If the resistance value is not between 368k ohm and 512k ohm (normal temperature), replace the Fixing Assembly. 3) If there is no induction between the connector (ACN) at the Fixing Assembly side and the connector (ACH) while the assembly is removed, replace the assembly. 4) Replace the Engine Controller PCB.
  • Code: E003 0001
  • Description: Abnormal low temperature in fixing (The sub thermistor detected a temperature of lower than 80 degree C for more than 2 seconds when 20 seconds elapsed after start of the power distribution to the heater.)
  • Remedy: 1) Reconnect the connector on the Engine Controller PCB. 2) Turn OFF the power supply switch, and remove the Fixing Assembly. Measure the resistance value between the connector (FSRTH) at the Fixing Assembly side and grounding. If the resistance value is not between 368k ohm and 512k ohm (normal temperature), replace the Fixing Assembly. 3) If there is no induction between the connector (ACN) at the Fixing Assembly side and the connector (ACH) while the assembly is removed, replace the assembly. 4) Replace the Engine Controller PCB.
  • Code: E004 0000
  • Description: Fixing assembly drive circuit failure
  • Remedy: 1) Reconnect the connector on the Engine Controller PCB. 2) Check the source of power supply for the printer. When using the power supply from the power generator and the like, improve the source of power supply. Note: If the frequency of power supply is not the specified range (40Hz to 70Hz), the fixing temperature control is not executed normally, so this might cause the damage. 3) Replace the Engine Controller PCB.