Brother MFC3100
Error Codes List page 8
|
|
- Code: BD
- Description: Black level data value too high.
- Causes: • CIS unit • Main PCB
- Code: Dx
- Description: Modem error.
- Causes: • Main PCB
- Code: E4
- Description: Out of recording paper.
- Causes: • ASF • Registration sensor actuator • Document feed roller • Main PCB
- Code: E6
- Description: Write error in EEPROM.
- Causes: • Main PCB
- Code: E8
- Description: Data scanning error during transmission.
- Causes: • CIS unit • Main PCB
- Code: EA
- Description: Document removed at phase B.
- Causes: