  • Code: 0504
  • Display: Print Unable 05
  • Description: After the center thermistor of the fuser unit was normally heated, it detected a temperature lower than the specified value.
  • Remedy: <User Check> - Turn the power OFF and ON again after several seconds to check if the error code disappears.
    1 Connection failure of the center or side thermistor harness of the fuser unit Check the harness connection of the center or side thermistor of the fuser unit and reconnect them.
    2 Connection failure of the heater harness of the fuser unit Check the harness connection of the heater of the fuser unit and reconnect it.
    3 Harness connection failure of the eject sensor PCB Check the harness connection of the eject sensor PCB and reconnect it.
    4 Harness connection failure of the low-voltage power supply PCB Check the harness connection of the low-voltage power supply PCB and reconnect it.
    5 Eject sensor PCB failure Replace the eject sensor PCB ASSY.
    6 Fuser unit failure Replace the fuser unit.
    7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
  • Code: 0505
  • Display: Print Unable 05
  • Description: The center thermistor of the fuser unit detected a temperature rise greater than the specified value within a set period of time.
  • Remedy: <User Check> - Turn the power OFF and ON again after several seconds to check if the error code disappears.
    1 Connection failure of the center or side thermistor harness of the fuser unit Check the harness connection of the center or side thermistor of the fuser unit and reconnect them.
    2 Connection failure of the heater harness of the fuser unit Check the harness connection of the heater of the fuser unit and reconnect it.
    3 Harness connection failure of the eject sensor PCB Check the harness connection of the eject sensor PCB and reconnect it.
    4 Harness connection failure of the low-voltage power supply PCB Check the harness connection of the low-voltage power supply PCB and reconnect it.
    5 Eject sensor PCB failure Replace the eject sensor PCB ASSY.
    6 Fuser unit failure Replace the fuser unit.
    7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
  • Code: 0506
  • Display: Print Unable 05
  • Description: The center thermistor of the fuser unit detected a temperature fall greater than the specified value within a set period of time.
  • Remedy: <User Check> - Turn the power OFF and ON again after several seconds to check if the error code disappears.
    1 Connection failure of the center or side thermistor harness of the fuser unit Check the harness connection of the center or side thermistor of the fuser unit and reconnect them.
    2 Connection failure of the heater harness of the fuser unit Check the harness connection of the heater of the fuser unit and reconnect it.
    3 Harness connection failure of the eject sensor PCB Check the harness connection of the eject sensor PCB and reconnect it.
    4 Harness connection failure of the low-voltage power supply PCB Check the harness connection of the low-voltage power supply PCB and reconnect it.
    5 Eject sensor PCB failure Replace the eject sensor PCB ASSY.
    6 Fuser unit failure Replace the fuser unit.
    7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
  • Code: 050A
  • Display: Print Unable 05
  • Description: The center thermistor or side thermistor of the fuser unit detected some temperature error in the hardware.
  • Remedy: <User Check> - Turn the power OFF and ON again after several seconds to check if the error code disappears.
    1 Connection failure of the center or side thermistor harness of the fuser unit Check the harness connection of the center or side thermistor of the fuser unit and reconnect them.
    2 Connection failure of the heater harness of the fuser unit Check the harness connection of the heater of the fuser unit and reconnect it.
    3 Harness connection failure of the eject sensor PCB Check the harness connection of the eject sensor PCB and reconnect it.
    4 Harness connection failure of the low-voltage power supply PCB Check the harness connection of the low-voltage power supply PCB and reconnect it.
    5 Eject sensor PCB failure Replace the eject sensor PCB ASSY.
    6 Fuser unit failure Replace the fuser unit.
    7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
    8 Main PCB failure Replace the main PCB ASSY.
  • Code: 050B
  • Display: Print Unable 05
  • Description: When the temperature of the center thermistor of the fuser unit is lower than the idle temperature, the side thermistor of the fuser unit detected a temperature higher than the specified value.
  • Remedy: <User Check> - Turn the power OFF and ON again after several seconds to check if the error code disappears.
    1 Connection failure of the center or side thermistor harness of the fuser unit Check the harness connection of the center or side thermistor of the fuser unit and reconnect them.
    2 Connection failure of the heater harness of the fuser unit Check the harness connection of the heater of the fuser unit and reconnect it.
    3 Harness connection failure of the eject sensor PCB Check the harness connection of the eject sensor PCB and reconnect it.
    4 Harness connection failure of the low-voltage power supply PCB Check the harness connection of the low-voltage power supply PCB and reconnect it.
    5 Eject sensor PCB failure Replace the eject sensor PCB ASSY.
    6 Fuser unit failure Replace the fuser unit.
    7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
    8 Main PCB failure Replace the main PCB ASSY.
  • Code: 050C
  • Display: Print Unable 05
  • Description: When the temperature of the center thermistor of the fuser unit is higher than the idle temperature, the side thermistor of the fuser unit detected a temperature lower than the specified value.
  • Remedy: <User Check> - Turn the power OFF and ON again after several seconds to check if the error code disappears.
    1 Connection failure of the center or side thermistor harness of the fuser unit Check the harness connection of the center or side thermistor of the fuser unit and reconnect them.
    2 Connection failure of the heater harness of the fuser unit Check the harness connection of the heater of the fuser unit and reconnect it.
    3 Harness connection failure of the eject sensor PCB Check the harness connection of the eject sensor PCB and reconnect it.
    4 Harness connection failure of the low-voltage power supply PCB Check the harness connection of the low-voltage power supply PCB and reconnect it.
    5 Eject sensor PCB failure Replace the eject sensor PCB ASSY.
    6 Fuser unit failure Replace the fuser unit.
    7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
    8 Main PCB failure Replace the main PCB ASSY.