  • Code: 050B
  • Display: Print Unable 05 Turn the power off and then back on again.
  • Description: When the center thermistor of the fuser unit was lower than the idle temperature, the side thermistor detected a temperature higher than the specified temperature.
  • Remedy: <User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the fuser unit heater harness Reconnect the fuser unit heater harness. 3 Connection failure of the eject sensor PCB flat cable Reconnect the eject sensor PCB flat cable. 4 Connection failure of the LVPS harness Reconnect the LVPS harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
  • Code: 050C
  • Display: Print Unable 05 Turn the power off and then back on again.
  • Description: When the center thermistor of the fuser unit was higher than the idle temperature, the side thermistor detected a temperature lower than the specified temperature.
  • Remedy: <User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the fuser unit heater harness Reconnect the fuser unit heater harness. 3 Connection failure of the eject sensor PCB flat cable Reconnect the eject sensor PCB flat cable. 4 Connection failure of the LVPS harness Reconnect the LVPS harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
  • Code: 050F
  • Display: Print Unable 05 Turn the power off and then back on again.
  • Description: An error occurred in the fuser unit.
  • Remedy: <User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the fuser unit heater harness Reconnect the fuser unit heater harness. 3 Connection failure of the eject sensor PCB flat cable Reconnect the eject sensor PCB flat cable. 4 Connection failure of the LVPS harness Reconnect the LVPS harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
  • Code: 0600
  • Display: Print Unable 06 Turn the power off and then back on again.
  • Description: A communication error occurred between the ASIC controlled by engine and the motor driver.
  • Remedy: 1 Main PCB failure Replace the main PCB ASSY.
  • Code: 0900
  • Display: Print Unable 09 Turn the power off and then back on again.
  • Description: Detected irregular power supply for more than 100 times.
  • Remedy: <User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. Refer to Reset irregular power supply detection counter of low-voltage power supply PCB (function code: 88)” to reset the irregular power supply detection counter. 2 Main PCB failure Replace the main PCB ASSY.
    • The irregular power supply detection error of the low-voltage power supply PCB (error code: 0900) occurs when there is a large distortion in the power supply voltage supplied to the machine. In this case, if the same power supply is used, the same error may occur even when the low-voltage power supply PCB ASSY is replaced. Ask the user to review the installation environment.
  • Code: 0A02
  • Display: Print Unable 0A Turn the power off and then back on again.
  • Description: Detected a fan failure.
  • Remedy: 1 Connection failure of the fan harness Reconnect the fan harness. 2 Connection failure of the HVPS flat cable Reconnect the HVPS flat cable. 3 Fan failure Replace the fan. 4 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 5 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 6 Main PCB failure Replace the main PCB ASSY.